An Italian expert consensus on the choice of the method of tip location for central venous access devices
Top Cited Papers
- 1 May 2025
- journal article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (1) , 12-25
Abstract
Tip location of central venous access devices is considered highly relevant for the purpose of reducing catheter-related complications and prolong the duration of the access. Though, the choice of the method of tip location currently relies upon the operator’s experience, preference, and training, on the local availability of specific resources and technologies, and on local policies. On the contrary, considering the relevance of tip location, such clinical choice should preferably be based on the best available evidence. Though current guidelines recommend intra-procedural rather than post-procedural methods of tip location, many clinicians still adopt the strategy of assessing the position of the tip by radiological methods after the completion of the procedure. Also, though current guidelines and evidence-based documents recommend the intra-cavitary electrocardiography and/or trans-thoracic echocardiography as preferred methods of intraprocedural tip location, many clinicians still adopt fluoroscopy. While the pros and cons of each different method of tip location are well known, there is no evidence-based document that offer robust recommendations about the choice of tip location of different central venous access devices in different population of patients (neonates, children, adults). Therefore, the Italian Group of Long-Term Venous Access Devices (GAVeCeLT) and the Italian Vascular Access Society (IVAS) have developed a national consensus on the choice of the most appropriate method of tip location. After a systematic review of the available evidence, the panel of the consensus (which included 22 Italian experts with documented competence in this area) has provided structured recommendations answering six key questions regarding the choice between intra-procedural and post-procedural tip location, as well as the appropriate indication of the four different methods of intra-procedural tip location currently available (trans-esophageal echocardiography, trans-thoracic echocardiography, intracavitary electrocardiography, and fluoroscopy). Only statements reaching a 100% agreement were included in the final recommendations.Keywords
This publication has 107 references indexed in Scilit:
- Vascular Access in Neonates and Children2022
- CT validation of SVC-RA junction location for pediatric central line placement: is vertebral bodies below the carina accurate?Pediatric Surgery International, 2020
- Comparison between ultrasonography and X-ray as evaluation methods of central venous catheter positioning and their complications in pediatricsPediatric Surgery International, 2020
- Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention studyEuropean Journal of Pediatrics, 2019
- Ultrasound‐Guided Umbilical Venous Catheter Insertion With Alignment of the Umbilical Vein and Ductus VenosusJournal of Ultrasound in Medicine, 2019
- Evidence‐Based Strategies and Recommendations for Preservation of Central Venous Access in ChildrenJournal of Parenteral and Enteral Nutrition, 2019
- Guidewire localization by transthoracic echocardiography during central venous catheter insertion: a periprocedural method to evaluate catheter placementIntensive Care Medicine, 2013
- Umbilical venous catheter position: evaluation by ultrasoundEuropean Radiology, 2011
- Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?Pediatric Radiology, 2006
- Cancer risks following diagnostic and therapeutic radiation exposure in childrenPediatric Radiology, 2006