Performance, Safety and Usability of a Third-Generation Continuous Glucose Monitoring System in a Pediatric Population: Results From a Prospective, Multicenter Study
Open Access
- 19 July 2026
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
Abstract
Background: A proprietary continuous glucose monitoring (CGM) system that uses third-generation sensor technology has previously been shown to exhibit stable, single-digit mean absolute relative difference (MARD) and 15-day wear life in adults with diabetes. Method: This was a prospective, single-arm study of pediatric participants aged 2 to 17 years that were enrolled at 3 clinical centers. Participants wore 2 sensors, one on each side of the abdomen, and were randomized to assessment of device performance on days 1 and 2, days 7 to 9 or days 15 and 16. Device performance across a range of metrics was assessed by comparison with venous blood glucose values obtained using a laboratory reference device. Per-protocol results are reported for the sensor with the inferior MARD. Results: The per-protocol set comprised 75 participants, of whom 16 were aged 2 to 5 years. The overall MARD was 8.89%, and MARDs at days 1 and 2, 7 to 9 and 15 and 16 were 8.65%, 8.70% and 9.30%, respectively. DTS error grid analyses showed that 100.0% of data pairs fell in clinically acceptable zones A+B. True alarm rates for hypoglycemia and hyperglycemia were high, at 98.6% and 98.8%, respectively. Mean sensor wear life was 14.4 days, and participant/guardian assessments of sensor usability revealed high satisfaction with respect to system assembly, sensor insertion and overall comfort. No device-related or skin-related adverse events were reported. Conclusions: In a pediatric population, the novel CGM system demonstrated accurate and stable performance across its 15-day wear life and showed high usability.Keywords
Funding Information
- Sinocare Inc. (The study was funded by Sinocare Inc.)
This publication has 12 references indexed in Scilit:
- 61st EASD Annual Meeting of the European Association for the Study of DiabetesDiabetologia, 2025
- The Diabetes Technology Society Error Grid and Trend Accuracy Matrix for Glucose MonitorsJournal of Diabetes Science and Technology, 2024
- Expanding the horizon of continuous glucose monitoring into the future of pediatric medicinePediatric Research, 2024
- 987-P: iCan CGM System—Performance Evaluation of a New CGM System with an Innovative Sensor TechnologyDiabetes, 2024
- Accuracy of the Third Generation of a 14-Day Continuous Glucose Monitoring SystemDiabetes Therapy, 2023
- ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Glucose monitoringPediatric Diabetes, 2022
- Accuracy of a Seventh-Generation Continuous Glucose Monitoring System in Children and Adolescents With Type 1 DiabetesJournal of Diabetes Science and Technology, 2022
- The management of type 1 diabetes in adults. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD)Diabetologia, 2021
- Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With DiabetesJournal of Diabetes Science and Technology, 2020
- Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird's Eye View of Glucose Sensing EnzymesJournal of Diabetes Science and Technology, 2011