Analyses of Structural Robustness of Prefabricated Modular Buildings: A Case Study on Mid-Rise Building Configurations
Authors:
- Thisari MunmullaThisari Munmulla
- Satheeskumar NavaratnamSatheeskumar Navaratnam
- Julian ThambooJTJulian Thamboo
- Thusiyanthan PonnampalamTPThusiyanthan Ponnampalam
- Hidallana-Gamage Hasitha DamruwanHDHidallana-Gamage Hasitha Damruwan
- Konstantinos Daniel TsavdaridisKonstantinos Daniel Tsavdaridis
- Guomin ZhangGuomin Zhang
Open Access
Abstract
The limited knowledge of the behaviour of modular buildings subjected to different loading scenarios and thereby lack of design guidelines hinder the growth of modular construction practices despite its widespread benefits. In order to understand the robustness of modular building systems, a case study was carried out using the numerical analysis method to evaluate the robustness of ten-storey braced frame modular buildings with different modular systems. Two types of modules with different span lengths were used in the assessments. Then, three different column removal scenarios involving (1) removal of a corner column, (2) an edge column, and (3) an interior column were employed to assess the robustness of modular building cases considered. The forces generated in the elements in close proximity to the removed column were verified to assess the robustness of each building case analysed. The results showed that the change in damping ratio from 1% to 5% has no significant influence on the robustness of the modular building cases considered, where the zero-damping leads to collapse. Corner column removal has not considerably affected the robustness of the braced modular building cases studied. The axial capacity ratio of columns is 0.8 in dynamic column removal in the building subjected to corner column removal, while in interior column removal capacity ratio reached up to 1.2, making it the most vulnerable failure scenario. Doubling the span of the modules (from 2.5 m to 5 m) has influenced the robustness of the buildings by increasing the axial forces of columns up to 30% in the interior column removal scenario. Thus, this study highlights that proper guidelines should be made available to assess the robustness of modular building systems to effectively design against progressive collapse.Keywords
Funding Information
- Ronnie & Koh Consultants Pte Ltd., Singapore
This publication has 42 references indexed in Scilit:
- Numerical study on the effects of diaphragm stiffness and strength on the seismic response of multi-story modular buildingsEngineering Structures, 2018
- Structural response of modular buildings – An overviewJournal of Building Engineering, 2018
- Nonlinear SDOF Model for Progressive Collapse Responses of Structures with Consideration of Viscous DampingJournal of Engineering Mechanics, 2017
- Design and compilation of specifications for a modular‐prefabricated high‐rise steel frame structure with diagonal braces. Part I: Integral structural designThe Structural Design of Tall and Special Buildings, 2017
- Finite element modelling of the structural response of roof to wall framing connections in timber-framed housesEngineering Structures, 2017
- Innovative composite steel-timber floors with prefabricated modular componentsEngineering Structures, 2017
- Life cycle performance of modular buildings: A critical reviewRenewable and Sustainable Energy Reviews, 2016
- Effect of span length on progressive collapse behaviour of steel moment resisting framesStructures, 2015
- Design in Modular Construction2014
- Assessment of progressive collapse-resisting capacity of steel moment framesJournal of Constructional Steel Research, 2009