Abstract
Tungsten brush accommodates thermal stresses and high heat flux in fusion reactor components such as plasma facing surfaces or armor. However, inherently higher surface areas are introduced with the brush design. We have tested a specific design of tungsten brush in steam between 500 and 1,100 C. Hydrogen generation and tungsten volatilization rates were determined to address fusion safety issues. The brush prepared from 3.2-mm diameter welding rods had a packing density of 85 percent. We found that both hydrogen generation and tungsten volatilization from brush, fixtured to represent a unit within a larger component, were less than projections based upon the total integrated surface area (TSA). Steam access and the escape of hydrogen and volatile oxide from void spaces within the brush are restricted compared to specimens with more direct diffusion pathways to the test environment. Hydrogen generation rates from restrained specimens based on normal surface area (NSA) remain about five times higher than rates based on total surface areas from specimens with direct steam access. Volatilization rates from restrained specimens based upon normal surface area (NSA) were only 50 percent higher than our historic cumulative maximum flux plot (CMFP) for tungsten. This study has shown that hydrogen generationmore » and tungsten volatilization from brush do not scale according to predictions with previously determined rates, but in fact, with higher packing density could approach those from flat surfaces. « less