The effects of bandpass filtering on the oscillatory potentials of the electroretinogram
- 7 March 2019
- journal article
- research article
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 138 (3) , 247-254
Abstract
Purpose In order to study the OPs, the ERG signal must be filtered to eliminate the low-frequency waves known as the a- and b-waves. Unfortunately, the ISCEV ERG standard does not give clear guidelines on how to proceed apart from indicating that frequencies below 75 Hz should be filtered out when recording scotopic OPs, while no suggestions are offered for the photopic OPs. The purpose of this study was thus to characterize more extensively the effects of various digital filters on the photopic OP waveforms in order to suggest the most appropriate filtering method to record them. Methods Filtered OPs (N = 9600 tracings) were extracted from a photopic ERG databank of 40 normal subjects [intensity: 4.4 cd s m−2; background: 30 cd m−2] using 240 different combinations of five digital filters types (Bessel; Butterworth; Elliptic; Chebyshev type 1 and 2), eight bandwidth ranges (50–300; 75–300; 100–300; 125–300; 50–1000; 75–1000; 100–1000; 125–1000 Hz), three filter orders (1, 2 and 5) and with/without phase lag corrections that were generated using MATLAB 2015b. The peak time and the percentage of OPs (sum of OP amplitudes on the b-wave amplitude) were calculated in the time domain (TD%OP). Results The timing of the OPs was less affected than the amplitude by the different filters used. Depending on the filter used, the resulting OPs were either severely depressed (16.16% of broadband OP content) or slightly reduced (93.63%). The filters that most successfully eliminated the slow components of the ERG (i.e., < 12% of broadband value) were the Bessel, the Butterworth and the Chebyshev type 1 filters and out of the latter, the Butterworth filter was that which most faithfully reproduced the high-frequency OPs (i.e., > 96%). Conclusion Our results vividly demonstrate the need to better define the characteristics of the filter that is used to record the OPs as it does have a significant impact on the resulting waveform.Keywords
Funding Information
- Canadian Institutes of Health Research (MOP-126082, ERA-132932)
- Santé (FRQ-S JTC 2013)
This publication has 20 references indexed in Scilit:
- Advance in ERG Analysis: From Peak Time and Amplitude to Frequency, Power, and EnergyBioMed Research International, 2014
- Classic Filter Design2011
- Asymmetrical growth of the photopic hill during the light adaptation effectDocumenta Ophthalmologica, 2010
- Wavelet analysis reveals dynamics of rat oscillatory potentialsJournal of Neuroscience Methods, 2008
- Oscillatory potentials of the slow-sequence multifocal ERG in primates extracted using the Matching Pursuit methodVision Research, 2007
- Modulation of the human photopic ERG luminance-response function with the use of chromatic stimuliVision Research, 2005
- Methodologic dependence of electroretinogram oscillatory potential amplitudesDocumenta Ophthalmologica, 1994
- The human suprathreshold photopic oscillatory potentials: Method of analysis and clinical applicationDocumenta Ophthalmologica, 1994
- Basic research and clinical aspects of the oscillatory potentials of the electroretinogramDocumenta Ophthalmologica, 1987
- Origin of the oscillatory potentials in the primate retinaVision Research, 1985