Simulations of foil-based spin-echo (modulated) small-angle neutron scattering with a sample using McStas
Open Access
- 1 February 2021
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 54 (1) , 195-202
Abstract
For the further development of spin-echo techniques to label elastic scattering it is necessary to perform simulations of the Larmor precession of neutron spins in a magnetic field. The details of some of these techniques as implemented at the reactor in Delft are simulated. First, the workings of the magnetized foil flipper are simulated. A full virtual spin-echo small-angle neutron scattering instrument is built and tested without and with a realistic scattering sample. It is essential for these simulations to have a simulated sample that also describes the transmitted beam of unscattered neutrons, which usually is not implemented for the simulation of conventional small-angle neutron scattering (SANS) instruments. Finally, the workings of a spin-echo modulated small-angle neutron scattering (SEMSANS) instrument are simulated. The simulations are in good agreement with theory and experiments. This setup can be extended to include realistic magnetic field distributions to fully predict the features of future Larmor labelling elastic-scattering instruments. Configurations can now be simulated for more complicated combinations of SANS with SEMSANS.Keywords
This publication has 31 references indexed in Scilit:
- Using a grating analyser for SEMSANS investigations in the very small angle rangePhysica B: Condensed Matter, 2012
- Combined SANS–SESANS, from 1nm to 0.1mm in one instrumentPhysica B: Condensed Matter, 2011
- McStas-model of the delft SESANSPhysica B: Condensed Matter, 2011
- Analysis of spin-echo small-angle neutron scattering measurementsJournal of Applied Crystallography, 2008
- Spin echo scattering angle measurement at a pulsed neutron sourceJournal of Applied Crystallography, 2008
- Comparison of the performance of SANS and SESANSPhysica B: Condensed Matter, 2004
- Ferromagnetic foils as monochromatic π flippers for application in spin-echo SANSPhysica B: Condensed Matter, 2003
- Real-space interpretation of spin-echo small-angle neutron scatteringJournal of Applied Crystallography, 2003
- Evaluation of double-crystal SANS data influenced by multiple scatteringJournal of Applied Crystallography, 2000
- McStas, a general software package for neutron ray-tracing simulationsNeutron News, 1999