Evaluation of low-volume post-dilution online hemodiafiltration with Japanese high-performance hemodiafilters
Open Access
- 1 September 2020
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 23 (3) , 234-239
Abstract
To assess the removal performance of low-volume post-hemodiafiltration (HDF) with Japanese hemodiafilters and the removal performance with 20 % reduction in the total dialysate flow rate (Q(d)total). Subjects were 8 patients undergoing pre-HDF. Study 1: Post-HDF was performed at a blood flow rate (Q(b)) of 250 mL/min and a total volume of substitution fluid (Vs) of 12 L/session(s) for 4 hrs using Fineflux-210Seco (FIX), ABH-21PA (ABH), and NVF-21H (NVF). We assessed removal efficiency of small molecular solutes, low-molecular-weight-proteins and the amount of albumin loss. Study 2: Post-HDF was performed at Vs of 12 L/s under G-1, Q(d)total of 500 and Q(b) of 250 mL/min; G-2, Q(d)total of 400 and Q(b) of 250 mL/min; and G-3, Q(d)total of 400 and Q(b) of 300 mL/min. Removal efficiency was compared and analyzed between these conditions. Subjects were 8 patients undergoing pre-HDF. Study 1: Post-HDF was performed at a blood flow rate (Q(b)) of 250 mL/min and a total volume of substitution fluid (Vs) of 12 L/session(s) for 4 hrs using Fineflux-210Seco (FIX), ABH-21PA (ABH), and NVF-21H (NVF). We assessed removal efficiency of small molecular solutes, low-molecular-weight-proteins and the amount of albumin loss. Study 2: Post-HDF was performed at Vs of 12 L/s under G-1, Q(d)total of 500 and Q(b) of 250 mL/min; G-2, Q(d)total of 400 and Q(b) of 250 mL/min; and G-3, Q(d)total of 400 and Q(b) of 300 mL/min. Removal efficiency was compared and analyzed between these conditions. Study 1: The results using FIX, ABH and NVF are shown in order. The Kt/V were 1.8, 1.9 and 1.8. The beta(2)-Microglobulin (MG) removal rate (RR) (%) were 81.2, 83.1 and 82.8, and the alpha(1)-MG RR were 37.4, 40.2 and 38.5, respectively. Study 2: The results in G-1, 2 and 3 are shown in order. The Kt/V and the RR of small solutes, were significantly higher in G-3. The beta(2)-MG RR (%) were 81.2, 80.1 and 81.0, and the alpha(1)-MG RR were 37.4, 37.5 and 38.0, respectively. ow-volume post-HDF performed at Q(b) of 250 mL/min with Japanese high-performance hemodiafilters exhibited favorable removal efficiency for all solutes. Even with 20 % reduction in Q(d)total, the removal performance was also favorable.Keywords
This publication has 14 references indexed in Scilit:
- Predilution online hemodiafiltration is associated with improved survival compared with hemodialysisKidney International, 2019
- Current approaches to middle molecule removal: room for innovationNephrology Dialysis Transplantation, 2018
- FP449COMPARISON OF THE EFFECTS OF PRE-DILUTION AND POST-DILUTION ON-LINE HEMODIAFILTRATION ON THE CELL SURFACE MARKER OF PLATELETS AND CYTOKINESNephrology Dialysis Transplantation, 2018
- Why choose high volume online post-dilution hemodiafiltration?Journal Of Nephrology, 2016
- Optimization of the convection volume in online post-dilution haemodiafiltration: practical and technical issuesClinical Kidney Journal, 2015
- Comparison of the effects of predilution and postdilution hemodiafiltration on neutrophils, lymphocytes and plateletsJournal of Artificial Organs, 2013
- High-Efficiency Postdilution Online Hemodiafiltration Reduces All-Cause Mortality in Hemodialysis PatientsJournal of the American Society of Nephrology, 2013
- Biomarkers for Evaluation of Clinical Outcomes of HemodiafiltrationBlood Purification, 2013
- Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF StudyNephrology Dialysis Transplantation, 2012
- Effect of Online Hemodiafiltration on All-Cause Mortality and Cardiovascular OutcomesJournal of the American Society of Nephrology, 2012