Semiautomated and Automated Quantitative Analysis of Corneal Sub-Basal Nerves in Patients With DED With Ocular Pain Using IVCM
Authors:
Open Access
- 11 February 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 831307
Abstract
Purpose: Investigate the correlation and agreement between the results of semiautomated and fully automated quantitative analysis of the corneal sub-basal nerve plexus (SNP) in patients with dry eye disease (DED) with ocular pain using in vivo confocal microscopy (IVCM).Method: A total of 50 voluntary participants were enrolled in this study, i.e., 25 DED patients with ocular pain and 25 healthy controls. Each patient underwent an evaluation of ocular symptoms that utilized: the Ocular Surface Disease Index (OSDI), the Ocular Pain Assessment Survey (OPAS), the tear film breakup time (TBUT) test, the Schirmer test, corneal staining, and IVCM. Five SNP images of the cornea of each eye were selected and analyzed using a semiautomated analysis software (NeuronJ) and a fully automated method (ACCMetrics) to quantify corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), and corneal nerve fiber length (CNFL).Results: The intraclass correlation coefficient (ICC) of the CNFD (0.460 [0.382–0.532], p < 0.001), CNBD (0.608 [0.545–0.665], p < 0.001), and CNFL (0.851 [0.822–0.875], p < 0.001) represents the repeatability and consistency of measurements by the NeuronJ and ACCMetrics software. The CNFL values (r = 0.881, p < 0.001) obtained using the two methods have extremely high correlation, and similarly, the CNFD values (r = 0.669, p < 0.001) and CNBD values (r = 0.703, p < 0.001) are highly correlated. The CNFL had the biggest area under the curve (AUC; 0.747 [0.700–0.793], p < 0.001) when using ACCMetrics. In DED patients with ocular pain, the mean CNFD values for semiautomated and fully automated quantization were 23.5 ± 8.1 and 23.8 ± 8.6 n/mm2; the mean CNBD values were 46.0 ± 21.3, 35.7 ± 23.3 n/mm2; and the mean CNFL values were 19.3 ± 4.3 and 15.2 ± 3.8 mm/mm2, which were significantly lower than healthy subjects (p < 0.001).Conclusion: There is a significant correlation between the measurements obtained via ACCMetrics and NeuronJ, especially for CNFL, which can be considered as the primary indicator in the diagnosis of DED with ocular pain. The SNP of the disease was significantly lower than that of healthy subjects.Keywords
Funding Information
- National Natural Science Foundation of China (81870624, 82171013)
- Science and Technology Program of Zhejiang Province (2022C03173)
This publication has 29 references indexed in Scilit:
- Prevalence of Diagnosed Dry Eye Disease in the United States Among Adults Aged 18 Years and OlderAmerican Journal of Ophthalmology, 2017
- A Novel Approach to Analyze the Progression of Measured Corneal Sub-Basal Nerve Fiber Length in Continuously Expanding Mosaic ImagesCurrent Eye Research, 2016
- Validity and Reliability of a Novel Ocular Pain Assessment Survey (OPAS) in Quantifying and Monitoring Corneal and Ocular Surface PainOphthalmology, 2016
- Corneal Dendritic Cell Density Is Associated with Subbasal Nerve Plexus Features, Ocular Surface Disease Index, and Serum Vitamin D in Evaporative Dry Eye DiseaseBioMed Research International, 2016
- Comparison of Standard Versus Wide-Field Composite Images of the Corneal Subbasal Layer by In Vivo Confocal MicroscopyInvestigative Ophthalmology & Visual Science, 2015
- Effects of Corneal Nerve Density on the Response to Treatment in Dry Eye DiseaseOphthalmology, 2015
- Local Variability of Parameters for Characterization of the Corneal Subbasal Nerve PlexusCurrent Eye Research, 2015
- Normative Values for Corneal Nerve Morphology Assessed Using Corneal Confocal Microscopy: A Multinational Normative Data SetDiabetes Care, 2015
- Fully Automated, Semiautomated, and Manual Morphometric Analysis of Corneal Subbasal Nerve Plexus in Individuals With and Without DiabetesCornea, 2014
- Morphology of Corneal Nerves Using Confocal MicroscopyCornea, 2001