Indoor Environmental Quality Evaluation of Lecture Classrooms in an Institutional Building in a Cold Climate
Open Access
- 22 November 2019
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 11 (23) , 6591
Abstract
In this paper, ventilation, indoor air quality (IAQ), thermal and acoustic conditions, and lighting were studied to evaluate the indoor environmental quality (IEQ) in an institutional building at the University of Alberta in Edmonton, Canada. This study examined IEQ parameters, including pressure, illuminance, acoustics, carbon dioxide (CO2) concentration, temperature, and humidity, with appropriate monitors allocated during a lecture (duration 50 min or 80 min) in four lecture classrooms repeatedly (N = 99) from October 2018 to March 2019 with the objectives of providing a comprehensive analysis of interactions between IEQ parameters. The classroom environments were maintained at 23 ± 1 °C and 33% ± 3% RH during two-season measurements. Indoor mean CO2 concentrations were 550–1055 ppm, and a mean sound level of 58 ± 3 dBA was observed. The air change rates were configured at 1.3–6.5 per hour based on continuous CO2 measurements and occupant loads in the lectures. A variance analysis indicated that the within-lecture classroom variations in most IEQ parameters exceeded between-lecture classrooms. A multilayer artificial neural network (ANN) model was developed on the basis of feedforward networks with a backpropagation algorithm. ANN results demonstrated the importance of the sequence of covariates on indoor conditions (temperature, RH, and CO2 level): Air change rate (ACR) > room operations (occupant number and light system) > outdoor conditions.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2018-05130)
This publication has 49 references indexed in Scilit:
- VOCs in industrial, urban and suburban neighborhoods, Part 1: Indoor and outdoor concentrations, variation, and risk driversAtmospheric Environment, 2008
- Particulate matter in the indoor air of classrooms—exploratory results from Munich and surrounding areaAtmospheric Environment, 2007
- Indoor air quality in Michigan schoolsIndoor Air, 2006
- Organic compounds in office environments - sensory irritation, odor, measurements and the role of reactive chemistryIndoor Air, 2006
- Personal exposures and microenvironment concentrations of PM2.5, VOC, NO2 and CO in Oxford, UKAtmospheric Environment, 2004
- Associations between classroom CO2 concentrations and student attendance in Washington and IdahoIndoor Air, 2004
- Relationship between outdoor and indoor air quality in eight French schoolsIndoor Air, 2004
- Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong KongScience of The Total Environment, 2004
- Indoor air quality, ventilation and health symptoms in schools: an analysis of existing informationIndoor Air, 2003
- VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, FinlandAtmospheric Environment, 2001