Kinetic–potentiometric determination of iodide with an antimony(V) coated-wire ion-selective electrode
Authors:
- Concepción Sánchez-PedreñoCSConcepción Sánchez-Pedreño
- Joaquín A. OrtuñoJOJoaquín A. Ortuño
- Ana L. RosARAna L. Ros
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 117 (10) , 1619-1621
Abstract
A coated-wire Sbv ion-selective electrode has been used to study the iodide-catalysed reaction between hexachloroantimonate(V) and hydroxylamine, and a kinetic method for the determination of iodide is proposed. Under the selected experimental conditions of 1 × 10–6 mol dm–3 SbCl6–, 8 × 10–2 mol dm–3 NH2OH, 1 × 10–1 mol dm–3 HCl and 25 ± 0.1 °C, iodide can be determined in the range 0.01–0.40 µg cm–3 with good selectivity. The method is simple and inexpensive and has been applied satisfactorily to the determination of iodide in common iodinated salts.Keywords
This publication has 12 references indexed in Scilit:
- Coated-wire ion-selective electrode for the determination of antimony(V)Analytical Chemistry, 1991
- Kinetic determination of iron(II) and of some α-hydroxyacids based on the accelerating action of iron(II) and hexacyanoferrate(II) on the α-hydroxyacid-periodate reactionsMicrochemical Journal, 1986
- Coated-wire ion-selective electrodesAnalytica Chimica Acta, 1986
- Catalytic determination of molybdenum(VI) by means of an iodide ion-selective electrode and a landolt-type hydrogen peroxide-iodide reactionTalanta, 1983
- Catalymetric determination of iron(III) and zirconium(IV) by their effects on the hydrogen peroxide-iodide reaction with the aid of iodide ion-selective electrode.BUNSEKI KAGAKU, 1982
- Kinetic study of the iron(II)-induced perbromate-iodide reaction with an iodide ion selective electrode and kinetic determination of iron, perbromate, ethylenediaminetetraacetic acid, diethylenetriaminepentaacetic acid, and ethylene glycol-bis(2-aminoethyl ether)-N,N,N',N'-tetraacetic acidAnalytical Chemistry, 1979
- Use of chloramine-T selective electrode in the kinetic microdetermination of iodide by means of its catalytic effect on the chloramine-T?hydrogen peroxide reactionMicrochimica Acta, 1978
- Automatic reaction rate method for the determination of vicinal glycols with a perchlorate ion selective electrodeAnalytical Chemistry, 1975
- Reaction rate measurements with cation-sensitive glass electrodes. Kinetic study of the exchange reaction between silver(I)-EDTA and nickel(II)Analytical Chemistry, 1967
- Electrometric stopped flow measurements of rapid reactions in solution. Part 2.—Glass electrode pH measurementsTransactions of the Faraday Society, 1958