A simple approach to modelling and control of DFIG-based WECS in network reference frame
- 18 March 2020
- journal article
- research article
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 2475-2485
Abstract
The control design of grid interfaced Doubly-Fed Induction Generator (DFIG) based Wind Energy Conversion Systems (WECS) requires the linear time invariant model of DFIG-WECS in a common reference frame called network reference frame. The transient analysis of DFIG-WECS requires the detailed modelling of both mechanical and electrical systems. In this paper, we present a simple approach to develop the mathematical modelling of DFIG-WECS, which consists of the equations to carry out the initial value calculation and transient analysis of grid connected DFIG-WECS in network reference frame. We use the Vector Control (VC) method to control the back-to-back converters of DFIG. The Stator Voltage Oriented Control (SVOC) is used to accomplish the decoupled vector control of DFIG. The performance analysis of grid connected DFIG-WECS is evaluated through the transient simulation under various disturbances. The results show that the transient performance of DFIG-WECS with proposed converter controllers is satisfactory under various disturbances.Keywords
This publication has 28 references indexed in Scilit:
- A comprehensive review on the grid integration of doubly fed induction generatorInternational Journal of Electrical Power & Energy Systems, 2013
- Wind energy development and its environmental impact: A reviewRenewable and Sustainable Energy Reviews, 2012
- Grid-connected vector-controlled slip-ring induction machine drive with out speed sensorSimulation Modelling Practice and Theory, 2010
- The art of modeling and simulation of induction generator in wind generation applications using high-order modelSimulation Modelling Practice and Theory, 2008
- Modeling of the Wind Turbine With a Doubly Fed Induction Generator for Grid Integration StudiesIEEE Transactions on Energy Conversion, 2006
- Doubly Fed Induction Generator Model for Transient Stability AnalysisIEEE Transactions on Energy Conversion, 2005
- Influence of the Variable-Speed Wind Generators in Transient Stability Margin of the Conventional Generators Integrated in Electrical GridsIEEE Transactions on Energy Conversion, 2004
- Dynamic modeling of doubly fed induction generator wind turbinesIEEE Transactions on Power Systems, 2003
- Doubly Fed Induction Generator Systems for Wind Turbines: A Viable Alternative to Adjust Speed over a Wide Range at Minimal CostIEEE Industry Applications Magazine, 2002
- Electricity use and economic developmentEnergy Policy, 2000