Impact of maternal weight on the intra‐observer and inter‐observer reproducibility of fetal ultrasonography measurements in the third trimester
- 31 October 2017
- journal article
- research article
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 140 (1) , 53-59
Abstract
Objective: To evaluate the effect of maternal weight on the intra‐ and inter‐observer reproducibility of third‐trimester ultrasonography fetal measurements.Methods: The present prospective study, performed at a tertiary hospital, enrolled patients at between 35+0 weeks and 36+6 weeks of singleton pregnancies between January 1, 2015, and July 1, 2016. Fetal ultrasonography measurements were evaluated twice by a first observer and a third time by a second observer. Intra‐ and inter‐observer consistency were analyzed using the Cronbach α reliability coefficient, and measurement reproducibility was compared with patients stratified by a body mass index (BMI, calculated as weight in kilograms divided by the square of height in meters) of below 25 or at least 25.Results: The study included 197 patients (133 with BMI <25 and 64 with BMI ≥25). Among patients with a BMI below 25, the reliability coefficients for bi‐parietal diameter, head circumference, abdominal circumference, and femur length measurements were 0.97, 0.95, 0.98, and 0.96, respectively, for intra‐observer consistency, and were 0.97, 0.93, 0.98, and 0.95, respectively, for inter‐observer consistency. Among patients with a BMI of at least 25, these values were 0.97, 0.96, 0.98, and 0.97, respectively, for intra‐observed consistency, and 0.97, 0.94, 0.98, and 0.96, respectively, for inter‐observer consistency.Conclusion: High intra‐ and inter‐observer reproducibility was observed for third‐trimester fetal ultrasonography measurements, including for patients who were overweight.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (SFRH/SINTD/92997/2013)
This publication has 18 references indexed in Scilit:
- Obesity and the challenges of ultrasound fetal abnormality diagnosisBest Practice & Research Clinical Obstetrics & Gynaecology, 2015
- Increasing Maternal Body Mass Index and the Accuracy of Sonographic Estimation of Fetal Weight Near DeliveryJournal of Ultrasound in Medicine, 2014
- Update on the Diagnosis and Classification of Fetal Growth Restriction and Proposal of a Stage-Based Management ProtocolFetal Diagnosis and Therapy, 2014
- Ultrasound methodology used to construct the fetal growth standards in the INTERGROWTH‐21st ProjectBJOG: An International Journal of Obstetrics & Gynaecology, 2013
- Factors affecting feasibility and quality of second‐trimester ultrasound scans in obese pregnant womenUltrasound in Obstetrics & Gynecology, 2012
- Fetal biometry by an inexperienced operator using two‐ and three‐dimensional ultrasoundUltrasound in Obstetrics & Gynecology, 2010
- Analysis of Factors Influencing the Ultrasonic Fetal Weight EstimationFetal Diagnosis and Therapy, 2008
- Clinical and sonographic estimation of fetal weight performed during labor by residentsAmerican Journal of Obstetrics and Gynecology, 2005
- Intraobserver and interobserver reproducibility of fetal biometryUltrasound in Obstetrics & Gynecology, 2004
- The effect of body mass index on three methods of fetal weight estimationBJOG: An International Journal of Obstetrics & Gynaecology, 2002