Robot-assisted stereotactic brainstem biopsy in children: prospective cohort study
Open Access
- 6 December 2018
- journal article
- research article
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 13 (4) , 575-579
Abstract
Tumours located within the brainstem comprise approximately a tenth of all paediatric brain tumours. Surgical biopsy of these tumours is technically challenging and has historically been associated with considerable risk. To this end, robot-assisted surgery theoretically allows for increased accuracy and precision. In this study we report our experience using the Neuromate robot (Renishaw, Gloucestershire, UK) to perform robot-assisted stereotactic biopsy in children with tumours located within the brainstem. An uncontrolled prospective cohort study was performed (phase II) according to the IDEAL model for safe surgical innovation. All cases were recorded on a prospectively maintained database. The database was searched over a 2-year period between the 1st December 2015 and the 31st November 2017 to identify all children with brainstem tumours that underwent robot-assisted stereotactic brain biopsy. When accessible, the post-operative MRI scans and pre-operative plans were compared to assess the target point localisation error (TPLE). Adverse events were recorded prospectively according to whether they resulted in increased hospital stay, caused neurological injury, or lead to death. In all, 11 consecutive children were identified with brain tumours located within the brainstem. In 10/11 cases specimens were diagnostic; in the remaining case a further biopsy was successful. The most frequent pathology was DIPG (7/15). Seven patients underwent an early post-operative volumetric MRI; the calculated median TPLE was 2.7 mm (range 0.5–4.2 mm). There were no surgical complications noted. Robot-assisted stereotactic biopsy in children appears to be feasible and safe. Research databases and comparative studies are warranted to further assess the technique.Keywords
This publication has 26 references indexed in Scilit:
- Surgical Robotics Through a Keyhole: From Today's Translational Barriers to Tomorrow's “Disappearing” RobotsIEEE Transactions on Biomedical Engineering, 2013
- Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safetyJournal of Neurosurgery, 2012
- Stereotactic Biopsy for Brainstem Tumors: Comparison of Transcerebellar with Transfrontal ApproachStereotactic and Functional Neurosurgery, 2012
- Stereotactic robot-guided biopsies of brain stem lesions: Experience with 15 casesNeurochirurgie, 2010
- Stereotactic biopsy for brainstem tumors in pediatric patientsChild's Nervous System, 2009
- Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holderActa Neurochirurgica, 2003
- Magnetic Resonance Scans Should Replace Biopsies for the Diagnosis of Diffuse Brain Stem GliomasNeurosurgery, 1993
- Computer- and Robot-assisted Resection of Thalamic Astrocytomas in ChildrenNeurosurgery, 1991
- Computer- and robot-assisted resection of thalamic astrocytomas in childrenNeurosurgery, 1991
- A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgeryIEEE Transactions on Biomedical Engineering, 1988