Truths and myths about the determination of molar mass distribution of synthetic and natural polymers by size exclusion chromatography
- 6 November 2013
- journal article
- research article
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 131 (7)
Abstract
This article discusses various aspects of the determination of molar mass distribution by means of size exclusion chromatography (SEC) in various application modes. The effects of erroneous specific refractive index increment (dn/dc), branching, column performance, and enthalpic interactions on the results obtained by different SEC techniques are discussed. Combination of SEC and a light scattering detector represents the most direct way to the molar mass distribution of all natural and synthetic polymers as it completely eliminates the need for column calibration and to a certain extent eliminates the dependence of the obtained results on some operational variables such as flow rate, temperature, or injected mass. A multiangle light scattering (MALS) photometer has become the most frequently used light scattering detector capable of determination of molecular size as another important polymer characteristic. This article contrasts SEC‐MALS method with other application modes of SEC from the viewpoint of some frequent confusions and misunderstandings. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40111.Keywords
This publication has 26 references indexed in Scilit:
- The SU(N) matrix model at two loopsJournal of High Energy Physics, 2005
- Are Molecular Weights of Proteins Determined by Superose 12 Column Chromatography Correct?Journal of Agricultural and Food Chemistry, 2004
- Experimental investigation on the reliability of routine SEC–MALLS for the determination of absolute molecular weights in the oligomeric rangePolymer, 2002
- Characterization of Low-Molecular-Weight Polymers: Failure of Universal Calibration in Size Exclusion ChromatographyInternational Journal of Polymer Analysis and Characterization, 1995
- A gel permeation chromatography calibration method for a broad molecular weight distribution polymerJournal of Applied Polymer Science, 1977
- Calibration procedures in gel permeation chromatographyBritish Polymer Journal, 1972
- A note on the universal calibration curve for gel permeation chromatographyJournal of Polymer Science Part B: Polymer Letters, 1969
- An Equilibrium Theory for Exclusion Chromatography of Branched and Linear Polymer ChainsMacromolecules, 1969
- Equilibrium distribution of flexible polymer chains between a macroscopic solution phase and small voidsJournal of Polymer Science Part B: Polymer Letters, 1967
- Treatment of Intrinsic ViscositiesJournal of the American Chemical Society, 1951