Estimation of corneal power after myopic laser refractive surgery: Comparison of methods against back-calculated corneal power
Authors:
- Eugene TayETEugene Tay
- Cindy LimCLCindy Lim
- Howard GimbelHGHoward Gimbel
- Geoffrey KayeGKGeoffrey Kaye
- 1 November 2011
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (11) , 1945-1950
Abstract
To compare methods of corneal power estimation after myopic laser refractive surgery with back-calculated corneal power (K). Private practice, Edmonton, Alberta, Canada. Case series. Patients with previous myopic laser surgery followed by cataract extraction were studied. Back-calculated K obtained with the Holladay IOL Consultant was compared with that obtained by the clinical history method (CHM), the modified Maloney method, an adaptation of the Maloney method using individualized Orbscan IIz-derived posterior corneal power values, Orbscan IIz quantitative area topography, and the Gaussian optics formula. A mixed effects linear model was used for analysis. The mean spherical equivalent (SE) before laser treatment was -6.43 diopters (D) ± 3.52 (SD). The estimated means of all methods except those obtained with the CHM, modified Maloney method, 2.0 mm total axial map, 1.5 mm total mean map, and 1.5 mm total optical map were significantly different from the mean of the back-calculated K. Estimates from the 1.5 mm total mean map were generally 0.06 D higher. The 2.0 mm total axial map, modified Maloney method, 1.5 mm total optical map, and CHM underestimated corneal power by 0.11 D, 0.13 D, 0.22 D, and 0.26 D, respectively. Unit increases in optical zone and pre-laser myopic SE were associated with decreases in corneal power of 1.58 D (P = .047) and 0.55 D (P = .0001), respectively. The modified Maloney method, 2.0 mm total axial map, 1.5 mm total mean map and 1.5 mm total optical map of the Orbscan IIz may provide estimates closer to the back-calculated K than the CHM. No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 11 references indexed in Scilit:
- Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics FormulaInvestigative Ophthalmology & Visual Science, 2011
- Calculation of Intraocular Lens Power Using Orbscan II Quantitative Area Topography After Corneal Refractive SurgeryJournal of Refractive Surgery, 2009
- Comparison of Techniques for Corneal Power Assessment After Myopic LASIK Without the Use of Preoperative DataJournal of Refractive Surgery, 2008
- Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopiaJournal of Cataract & Refractive Surgery, 2007
- Comparison of intraocular lens power calculation methods in eyes that have undergone LASIKOphthalmology, 2004
- Intraocular Lens Power Calculation in Eyes After Corneal Refractive SurgeryJournal of Refractive Surgery, 2000
- Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999
- The prediction of surgically induced refractive change from corneal topographyAmerican Journal of Ophthalmology, 1998
- Intraocular Lens Power Calculation for Eyes After Refractive KeratotomyJournal of Refractive Surgery, 1995
- Refractive Complications of Cataract Surgery After Radial KeratotomyAmerican Journal of Ophthalmology, 1989