Immobilization using dental material casts facilitates accurate serial and multimodality small animal imaging
Authors:
- 8 April 2008
- journal article
- research article
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 33B (2) , 138-144
Abstract
Custom disposable patient immobilization systems that conform to the patient's body contours are commonly used to facilitate accurate repeated patient setup for imaging and treatment in radiation therapy. However, in small‐animal imaging, immobilization is often overlooked or done in a way that is not conducive to reproducible positioning. This has a negative impact on the potential for accurate analysis of serial or multimodality imaging. We present the use of vinyl polysiloxane dental impression material for immobilization of mice for imaging. Four different materials were examined to identify any potential artifacts using magnetic resonance techniques. A water phantom placed inside the cast was used at 4.7 T with magnetic resonance imaging and showed no effect at the center of the image when compared with images without the cast. A negligible effect was seen near the ends of the coil. Each material had no detectable signal using electron paramagnetic resonance imaging at 9 mT. The use of dental material also greatly enhances the use of fiducial markers that can be embedded in the mold. Therefore, image registration is simplified as the immobilization of the animal and fiducials together helps in translating from one image coordinate system to another. © 2008 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 33B: 138–144, 2008Keywords
This publication has 6 references indexed in Scilit:
- Concerning the preparation and use of substances with a magnetic susceptibility equal to the magnetic susceptibility of airMagnetic Resonance in Medicine, 2006
- Animal-specific positioning molds for registration of repeat imaging studies: comparative microPET imaging of F18-labeled fluoro-deoxyglucose and fluoro-misonidazole in rodent tumorsNuclear Medicine and Biology, 2006
- A Methodology for Registration of a Histological Slide and In Vivo MRI Volume Based on Optimizing Mutual InformationMolecular Imaging, 2006
- Susceptibility-matched envelope for the correction of EPI artifactsMagnetic Resonance Imaging, 2005
- Correcting spatial distortion in histological imagesComputerized Medical Imaging and Graphics, 2005
- A stereotactic method for the three‐dimensional registration of multi‐modality biologic images in animals: NMR, PET, histology, and autoradiographyMedical Physics, 2003