Incorporation of a nanosplitter interface into an LC‐MS‐RD system to facilitate drug metabolism studies
- 29 November 2005
- journal article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 41 (1) , 43-49
Abstract
In the work reported here, a novel interface, the nanosplitter, is incorporated into the drug metabolism laboratory in order to enhance the analytical capabilities of detecting and identifying drug‐related metabolites to support drug metabolism studies during the drug development process. When an existing LC‐MS‐radiometric detector (RD) system is coupled with this nanosplitter, the system becomes capable of performing dynamic microspray under a typical analytical LC method. With the superior MS sensitivity offered by this system, most of the analytical LC methods developed for metabolite profiling can then be easily adopted for metabolite identification work. The improvement of these analytical capabilities can streamline the entire process of the drug metabolism study. In the experiments presented here, the nanosplitter interface coupled with analytical HPLC systems (e.g. 4.6 × 250 mm column @ 1 ml/min) demonstrated significant increases in MS signal (2× to 40× peak area) when compared to the standard LC‐MS interface for both in vitro and in vivo metabolism studies. Furthermore, this signal gain facilitated the MS detection of additional metabolites (observed in the radiometric trace) that were below the MS level of detection when using the standard interface. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 21 references indexed in Scilit:
- Addressing the metabolic activation potential of new leads in drug discovery: a case study using ion trap mass spectrometry and tritium labeling techniquesJournal of Mass Spectrometry, 2003
- Investigation of matrix effects in bioanalytical high‐performance liquid chromatography/tandem mass spectrometric assays: application to drug discoveryRapid Communications in Mass Spectrometry, 2002
- Determination of lamivudine/stavudine/efavirenz in human serum using liquid chromatography/electrospray tandem mass spectrometry with ionization polarity switchBiomedical Chromatography, 2002
- Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast‐gradient liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2001
- Reduction of Signal Suppression Effects in ESI-MS Using a Nanosplitting DeviceAnalytical Chemistry, 2001
- Determination of the site of glucuronidation in anN-(3,5-dichlorophenyl)succinimide metabolite by electrospray ionization tandem mass spectrometry following derivatization to picolinyl estersRapid Communications in Mass Spectrometry, 2000
- Biomedical applications of accelerator mass spectrometry-isotope measurements at the level of the atomRapid Communications in Mass Spectrometry, 1999
- Liquid Chromatography/Chemical Reaction Interface Mass Spectrometry as an Alternative to Radioisotopes for Quantitative Drug Metabolism StudiesAnalytical Chemistry, 1996
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- Liquid chromatography mass spectrometry in the pharmaceutical industry: Objectives and needsJournal of Chromatography A, 1982