Videolaryngoscopy is associated with a lower rate of double-lumen endotracheal tube malposition in thoracic surgery procedures, retrospective single-center study
Open Access
- 4 January 2025
- journal article
- research article
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 20 (1) , 1-6
Abstract
The optimal positioned double-lumen endotracheal tubes (DLT) is crucial in thoracic surgery requiring lung isolation. This study aims to compare the accuracy and complication rates of DLT placement using videolaryngoscopy (VL) versus conventional direct laryngoscopy (DL). This retrospective single-center study included 89 patients who underwent thoracic surgery with DLT placement between July 2023 and May 2024. Patients were divided into two groups: VL (n = 45) and DL (n = 44). Patient characteristics, intubation times, malposition rates, and complications were recorded. DLT position was confirmed using fiberoptic bronchoscopy. The incidence of DLT malposition was significantly lower in the VL group (13.3%) compared to the DL group (31.8%) (p = 0.037). The overall complication rate was also lower in the VL group (4.4%) compared to the DL group (11.4%) (p = 0.024). The mean time from anesthesia induction to the first incision was shorter in the VL group (25.2 ± 6.1 min) than in the DL group (28.3 ± 6.5 min) (p = 0.02). VL significantly reduces the incidence of DLT malposition and associated complications in thoracic surgery compared to DL. The improved visualization and multiple blade options of the C-MAC videolaryngoscopy set likely contribute to these findings. Further research is warranted to confirm these results in larger, multicenter studies. Institutional Review Board (Registration number: 80576354-050-99/437, 27.06.2024).Keywords
All Related Versions
This publication has 16 references indexed in Scilit:
- Lung Isolation for Thoracic Surgery: From Inception to Evidence-BasedJournal of Cardiothoracic and Vascular Anesthesia, 2017
- How clinical experience leads anesthetists in the choice of double-lumen tube sizeJournal of Clinical Anesthesia, 2016
- Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniquesBMC Anesthesiology, 2015
- VideolaryngoscopyInternational Journal of Critical Illness and Injury Science, 2014
- A randomised controlled trial comparing the GlideScope ® and the Macintosh laryngoscope for double‐lumen endobronchial intubationAnaesthesia, 2013
- Comparison of the GlideScope ® videolaryngoscope and the Macintosh laryngoscope for double‐lumen tube intubationAnaesthesia, 2012
- Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: a randomised, prospective trial.2009
- Using a Glidescope for intubation with a double lumen endotracheal tubeCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Tracheobronchial rupture after double-lumen endotracheal intubationJournal of Cardiothoracic and Vascular Anesthesia, 2004
- Malposition of Left-sided Double-lumen Endobronchial TubesAnesthesiology, 1985