Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction
Authors:
- Terrence D. RuddyTRTerrence D. Ruddy
- Abdulaziz AlmgrahiAAAbdulaziz Almgrahi
- Frank G. AnstettFAFrank G. Anstett
- R. Glenn WellsRWR. Glenn Wells
- 16 March 2009
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (4) , 554-562
Abstract
Reducing acquisition time may improve patient throughput, increase camera efficiency, and reduce costs; reducing acquisition time also increases image noise. Newly available software controls the effects of noise by maximum a posteriori reconstruction while maintaining resolution with resolution-recovery methods. This study compares half-time (HT) gated myocardial SPECT images processed with ordered-subset expectation maximization with resolution recovery (OSEM-RR) (with and without CT-based attenuation correction [AC]) with full-time (FT) images obtained with a standard clinical protocol and reconstructed with filtered backprojection (FBP) and OSEM (with and without AC). A total of 212 patients (mean age, 57 y; age range, 27-86 y) underwent 1-d rest/stress (99m)Tc-tetrofosmin gated SPECT. FT (12.5 min, both rest and stress) and HT (rest, 7.5 min; stress, 6.0 min) images were acquired with low-dose CT for AC in 112 patients. HT acquisitions were processed with OSEM-RR (with and without AC) using software, and FT acquisitions were processed with FBP and OSEM (with and without AC). In another 100 patients, test-retest repeatability was assessed using 2 sets of FT images (FBP reconstruction) that were acquired one immediately after the other. Radiologists unaware of the acquisition and reconstruction protocols visually assessed all reconstructed images for summed stress, summed rest, and summed difference scores and regional wall motion using a 17-segment model. Automated analysis on gated SPECT was used to determine left ventricular volumes, ejection fraction, and dilation (end-diastolic volume, end-systolic volume, left ventricular ejection fraction, and transient ischemic dilation [TID]). A clinical diagnosis was also determined. All measurements resulted in significant correlations (P < 0.01) between the HT and FT images. The only significant difference in mean values was for OSEM-RR plus AC; this method led to an increase in TID by 4% over FT imaging. The concordance in the clinical diagnosis for HT versus FT was 106 to 112 (kappa = 0.88) for no AC and 102 to 106 (kappa = 0.91) for AC, similar to the repeatability of FT versus FT (98/100, kappa = 0.95). HT images processed with the new algorithm provided a clinical diagnosis in concordance with that from FT images in 95% (no AC) to 96% (AC) of cases. This concordance is similar to the test-retest repeatability of FT imaging.Keywords
This publication has 15 references indexed in Scilit:
- Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojectionJournal of Nuclear Cardiology, 2008
- Myocardial perfusion and function: Single photon emission computed tomographyJournal of Nuclear Cardiology, 2007
- Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studiesJournal of Nuclear Cardiology, 2007
- Stress protocols and tracersJournal of Nuclear Cardiology, 2006
- Technetium99msestamibi myocardial perfusion imaging predicts clinical outcome in the community outpatient settingJACC, 2004
- Transient ischemic dilation ratio of the left ventricle is a significant predictor of future cardiac events in patients with otherwise normal myocardial perfusion SPECTJACC, 2003
- LROC analysis of detector-response compensation in SPECTIEEE Transactions on Medical Imaging, 2000
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- The geometric transfer function for cone and fan beam collimatorsPhysics in Medicine & Biology, 1990
- The geometric transfer function component for scintillation camera collimators with straight parallel holesPhysics in Medicine & Biology, 1980