The influence of axial length on confocal scanning laser ophthalmoscopy and spectral-domain optical coherence tomography size measurements: a pilot study
Authors:
- 23 February 2014
- journal article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 252 (4) , 589-593
Abstract
To investigate the influence of axial length on SD-OCT and cSLO size measurements from the Heidelberg Spectralis. In this pilot study, eight emmetropic pseudophakic eyes with subretinal visual implant were selected. The axial length was measured in three short (25.52 mm) eyes. The known size of subretinal implant sensor field (2800 × 2800 μm) was measured on 15 images per eye with cSLO and SD-OCT. The mean axial length was 20.8 ± 0.8 mm in short eyes, 23.3 ± 0.4 mm in medium eyes, and 26.3 ± 0.5 mm in long eyes respectively. We found in short eyes, in medium eyes and in long eyes a mean value of sensor field size measurements from cSLO of 3327 ± 9 μm, 2800 ± 9 μm and 2589 ± 12 μm and from SD-OCT of 3328 ± 9 μm, 2800 ± 12 μm and 2585 ± 19 μm respectively. The size measurements decreased in SD-OCT and cSLO measurements with longer axial lengths significantly (p The present findings demonstrate accuracy of the scaling in cSLO and SD-OCT measurements of the Heidelberg Spectralis for emmetropic medium eyes. The size measurements from SD-OCT to those from cSLO were approximately equal. Caution is recommended when comparing the measured values of short and long eyes with the normative database of the instrument. Further studies with larger sample sizes are needed to confirm findings.Keywords
This publication has 25 references indexed in Scilit:
- Artificial vision with wirelessly powered subretinal electronic implant alpha-IMSProceedings Of The Royal Society B-Biological Sciences, 2013
- Enzymatic Vitreolysis with Ocriplasmin for Vitreomacular Traction and Macular HolesNew England Journal of Medicine, 2012
- Spectral-Domain Optical Coherence Tomography as a Noninvasive Method to Assess Damaged and Regenerating Adult Zebrafish RetinasInvestigative Ophthalmology & Visual Science, 2012
- HEIDELBERG SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHIC FINDINGS IN RETINAL ARTERY MACROANEURYSMRetina, 2012
- Subretinale visuelle ImplantateKlinische Monatsblätter für Augenheilkunde, 2010
- Subretinal electronic chips allow blind patients to read letters and combine them to wordsProceedings Of The Royal Society B-Biological Sciences, 2010
- Retinal optical coherence tomography: past, present and future perspectivesBritish Journal of Ophthalmology, 2010
- DYNAMICS OF THE MACULAR HOLE-SILICONE OIL TAMPONADE INTERFACE WITH PATIENT POSITIONING AS IMAGED BY SPECTRAL DOMAIN-OPTICAL COHERENCE TOMOGRAPHYRetina, 2010
- Measurement of optic disc parameters on digital fundus photographs: algorithm development and evaluationActa Ophthalmologica, 2008
- Magnification characteristics of the Optical Coherence Tomograph STRATUS OCT 3000Ophthalmic and Physiological Optics, 2008