Clinical Real‐Time Monitoring of Gaseous Microemboli in Pediatric Cardiopulmonary Bypass
- 23 November 2009
- journal article
- Published by Wiley in Artificial Organs
- Vol. 33 (11) , 1026-1030
Abstract
We describe the occurrence and distribution of gaseous microemboli with real‐time monitoring in a pediatric cardiopulmonary bypass (CPB) circuit and in the cerebral circulation of patients using the Emboli Detection and Classification (EDAC) system and transcranial Doppler (TCD). Four patients (weights 3.2–13.8 kg) were studied. EDAC monitors were located on the venous line and on the postfilter arterial line to measure gaseous microemboli in the CPB circuit. TCD was used to measure high‐intensity transient signals (HITS) in the middle cerebral artery. Before the initiation of CPB, EDAC detected gaseous microemboli in two cases when giving volume through the arterial line. At the initiation of CPB, gross air appeared in the venous line and gaseous microemboli were detected in the arterial line in all patients. EDAC detected a total of 3192–14 699 gaseous microemboli in the arterial line during the whole CPB period, more than 99% of which were smaller than 40 microns. After cessation of CPB, EDAC detected gaseous microemboli in the arterial line in all cases. The TCD detected HITS in two cases (25 and 315), and detected no HITS in two cases. We observed that the venous line acted as a principal source of gaseous microemboli, particularly when using vacuum‐assisted venous drainage, and that a significant number of these gaseous microemboli smaller than 40 microns were subsequently transferred to the patient. Using EDAC and TCD together could strengthen the monitoring of gaseous microemboli in the extracorporeal circuit and cerebral circulation.Keywords
This publication has 10 references indexed in Scilit:
- Delivery of Gaseous Microemboli With Vacuum-Assisted Venous Drainage During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal Cardiopulmonary Bypass ModelASAIO Journal, 2008
- Microemboli Detection and Classification by Innovative Ultrasound Technology During Simulated Neonatal Cardiopulmonary Bypass at Different Flow Rates, Perfusion Modes, and Perfusate TemperaturesASAIO Journal, 2008
- Arterial Line Filters Ranked for Gaseous Micro-Emboli Separation Performance: An In Vitro StudyThe Journal of ExtraCorporeal Technology, 2008
- Detection and Classification of Gaseous Microemboli During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal CPB ModelASAIO Journal, 2007
- Gaseous Microemboli Sizing in Extracorporeal Circuits Using Ultrasound BackscatterUltrasound in Medicine & Biology, 2007
- Factors Influencing Neurologic Outcome After Neonatal Cardiopulmonary Bypass: What We Can and Cannot ControlThe Annals of Thoracic Surgery, 2006
- How Effective Are Cardiopulmonary Bypass Circuits at Removing Gaseous Microemboli?The Journal of ExtraCorporeal Technology, 2002
- Evaluation of New Online Automated Embolic Signal Detection Algorithm, Including Comparison With Panel of International ExpertsStroke, 2000
- Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventionsThe Annals of Thoracic Surgery, 1999
- Cooling Gradients and Formation of Gaseous Microemboli With Cardiopulmonary Bypass: An Echocardiographic StudyThe Annals of Thoracic Surgery, 1997