Comparative Analysis of Corneal Parameters in Swept-Source Imaging between DMEK and UT-DSAEK Eyes
Open Access
- 30 October 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (21) , 5119
Abstract
Background: The need to provide a comparative analysis of corneal parameter changes compared to their preoperative values between Descemet membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) patients. Methods: The study included 24 eyes after UT-DSAEK and 24 eyes after DMEK. Visual acuity, endothelial cell count (ECC), central corneal thickness (CCT), mean keratometry (MK), mean astigmatism (MA), astigmatism asymmetry (AA) and higher-order aberrations (HOAs) were assessed at baseline and 1, 3, 6 and 12 months after the surgery. Results: From the 3rd month post operation, ECC was higher in the DMEK eyes than in the UT-DSAEK eyes (p = 0.01). In a bivariate analysis that was adjusted for age, DMEK was associated with a smaller decrease in posterior MK at the 1-month (β = −0.49, p = 0.002), 3-month (β = −0.50, p < 0.001), 6-month (β = −0.58, p < 0.001) and 12-month (β = −0.49, p < 0.001) follow-up visits. There were no significant differences in changes in anterior or combined surface MK throughout the observation period. Accordingly, no significant differences in changes in MA, AA or HOAs compared to the baseline values were identified between the eyes after DMEK and UT-DSAEK at any follow-up time point. Conclusions: UT-DSAEK seemed to be an easier and safer technique than DMEK while maintaining similar outcomes regarding irregular astigmatism and total keratometry values.Keywords
This publication has 21 references indexed in Scilit:
- Descemet Endothelial Thickness Comparison TrialOphthalmology, 2019
- Efficacy and safety of Descemet’s membrane endothelial keratoplasty versus Descemet’s stripping endothelial keratoplasty: A systematic review and meta-analysisPLOS ONE, 2017
- A Randomized Multicenter Clinical Trial of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) versus DSAEKOphthalmology, 2016
- Contralateral Eye Comparison of Descemet Membrane Endothelial Keratoplasty and Descemet Stripping Automated Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2015
- Retrospective contralateral study comparing Descemet membrane endothelial keratoplasty with Descemet stripping automated endothelial keratoplastyEye, 2014
- Ultrathin Descemet's Stripping Automated Endothelial Keratoplasty with the Microkeratome Double-Pass TechniqueOphthalmology, 2013
- Descemet Stripping Endothelial KeratoplastyDeutsches Ärzteblatt international, 2013
- Sample size calculation in medical studies2013
- Endothelial Keratoplasty: Fellow Eyes Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial KeratoplastyCornea, 2011
- Descemet's Stripping Endothelial Keratoplasty: Safety and OutcomesOphthalmology, 2009