Amplitude cancellation reduces the size of motor unit potentials averaged from the surface EMG
Authors:
- Kevin G. KeenanKKKevin G. Keenan
- Dario FarinaDFDario Farina
- Roberto MerlettiRMRoberto Merletti
- Roger M. EnokaRERoger M. Enoka
- 1 June 2006
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 100 (6) , 1928-1937
Abstract
The purpose of the study was to evaluate the influence of selected physiological parameters on amplitude cancellation in the simulated surface electromyogram (EMG) and the consequences for spike-triggered averages of motor unit potentials derived from the interference and rectified EMG signals. The surface EMG was simulated from prescribed recruitment and rate coding characteristics of a motor unit population. The potentials of the motor units were detected on the skin over a hand muscle with a bipolar electrode configuration. Averages derived from the EMG signal were generated using the discharge times for each of the 24 motor units with lowest recruitment thresholds from a population of 120 across three conditions: 1) excitation level; 2) motor unit conduction velocity; and 3) motor unit synchronization. The area of the surface-detected potential was compared with potentials averaged from the interference, rectified, and no-cancellation EMGs. The no-cancellation EMG comprised motor unit potentials that were rectified before they were summed, thereby preventing cancellation between the opposite phases of the potentials. The percent decrease in area of potentials extracted from the rectified EMG was linearly related to the amount of amplitude cancellation in the interference EMG signal, with the amount of cancellation influenced by variation in excitation level and motor unit conduction velocity. Motor unit synchronization increased potentials derived from both the rectified and interference EMG signals, although cancellation limited the increase in area for both potentials. These findings document the influence of amplitude cancellation on motor unit potentials averaged from the surface EMG and the consequences for using the procedure to characterize motor unit properties.Keywords
This publication has 69 references indexed in Scilit:
- Coherence at 16-32 Hz Can Be Caused by Short-Term Synchrony of Motor UnitsJournal of Neurophysiology, 2005
- Discharge Rate Variability Influences the Variation in Force Fluctuations Across the Working Range of a Hand MuscleJournal of Neurophysiology, 2005
- Decomposition‐based quantitative electromyography: Effect of force on motor unit potentials and motor unit number estimatesMuscle & Nerve, 2004
- Factors Governing the Form of the Relation Between Muscle Force and the EMG: A Simulation StudyJournal of Neurophysiology, 2004
- Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arraysIEEE Transactions on Biomedical Engineering, 2000
- Parameters of human motor unit twitches obtained by intramuscular microstimulationNeuromuscular Disorders, 1992
- Methods for estimating the number of motor units in human musclesAnnals of Neurology, 1990
- Coherent averaging technique: A tutorial review Part 2: Trigger jitter, overlapping responses and non-periodic stimulationJournal of Biomedical Engineering, 1986
- Coherent averaging technique: A tutorial review Part 1: Noise reduction and the equivalent filterJournal of Biomedical Engineering, 1986
- Electrophysiological cross section of the motor unit.Journal of Neurology, Neurosurgery & Psychiatry, 1980