Abstract
The present study aimed to assess whether arterial carbon dioxide pressure (Pa,CO2) has an impact on agreement between oxygen saturation measured with pulse oximetry (Sp,O2) or arterial blood gas co-oximetry (Sa,O2).Sa,O2andSp,O2determinations were obtained simultaneously from 846 patients under assessment for long-term home oxygen therapy in a specialised outpatient clinic. Both measurements were taken with patients seated and breathing room air.Agreement betweenSa,O2andSp,O2 results was analysed by the Bland–Altman method and the Lin concordance coefficient. In addition, potential interactions of arterial oxygen tension (Pa,O2) orPa,CO2on agreement were analysed by adjusted multivariate analysis.Upon comparison ofSa,O2andSp,O2results, the Bland–Altman technique yielded a bias (95% confidence interval (CI)) of -1.24 (-6.86–4.38) and -1.32 (-7.78–5.15) when Pa,CO2>48 mmHg (6.39 kPa) orPa,O2Pa,O2,Pa,CO2and bicarbonate on bias, showed thatPa,O2,Pa,CO2and their interaction terms were the most important predictors of the bias (standardised estimates of -0.54, -0.94, and 0.85, respectively). The effect of pH, although statistically significant, was small, and bicarbonate had no significant effect.Arterial carbon dioxide pressure status can contribute to impaired agreement between arterial oxygen saturation and arterial oxygen saturation measured with pulse oximetry, particularly in patients with hypercapnia.