Quasi-Static and Harmonic Indentation of Osteonal Bone
Authors:
Open Access
- 1 January 2010
- journal article
- Published by Portico in Journal of Dental Biomechanics
- Vol. 1 (1) , 736830
Abstract
The purpose of the study was to compare Quasi-Static (QS) and harmonic (CSM) methods of indentation testing. Bone sections were obtained from mid-femoral diaphyses of dogs which received a pair of calcein labels. Labeled (n = 35) and unlabeled (n = 112) osteons were identified. Indentation modulus (IM) and hardness (H) for the CSM method were collected during the entire loading cycle to peak depth, while IM and H for QS method were calculated at a peak depth of 500 nm. Results: The mean (SD) of the IM and H for labeled osteons were as follows: QS IM = 15.3 GPa (3.85) versus CSM IM = 14.7 GPa (3.58); P = .52 and QS H = .39 GPa (.171) versus CSM H = .42 GPa (.146); P = .32. The mean (SD) of the IM and H for unlabeled osteons were as follows: QS IM = 21.5 GPa (2.80) versus CSM IM = 20.6 GPa (2.53); P = .054 and QS H = .64 GPa (.117) versus CSM H = .70 GPa (.120); P = .017. There was no difference in IM and H for the two methods, except for H of the unlabeled osteons. In addition, for the CSM method, IM at 100 nm, 200 nm, 300 nm, 400 nm and 500 nm were not statistically significant different (P = .06). Bone is viscoelastic at an organ level. However, this component of its behavior was not detected at the length scale examined.Keywords
This publication has 19 references indexed in Scilit:
- The use of nanoindentation for characterizing the properties of mineralized hard tissues: State‐of‐the art reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Indentation Modulus of the Alveolar Process in DogsJournal of Dental Research, 2007
- Indentation Properties of Young and Old OsteonsCalcified Tissue International, 2006
- Atomic force microscopy and nanoindentation characterization of human lamellar bone prepared by microtome sectioning and mechanical polishing techniqueJournal of Biomedical Materials Research Part A, 2003
- Effects of viscoelasticity and time‐dependent plasticity on nanoindentation measurements of human cortical boneJournal of Biomedical Materials Research Part A, 2003
- Relationship between ultrastructure and the nanoindentation properties of intramuscular herring bones.Annals of Biomedical Engineering, 2001
- Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentationBiomaterials, 1997
- Basic biomechanical measurements of bone: A tutorialBone, 1993
- Viscoelastic properties of wet cortical bone—I. Torsional and biaxial studiesJournal of Biomechanics, 1979
- Viscoelastic properties of wet cortical bone—III. A non-linear constitutive equationJournal of Biomechanics, 1979