A randomized prospective study comparing two flexible epidural catheters for labour analgesia
Authors:
- J.E. SpiegelJSJ.E. Spiegel
- A. VasudevanAVA. Vasudevan
- Y. LiYLY. Li
- P.E. HessPHP.E. Hess
- 1 September 2009
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 103 (3) , 400-405
Abstract
Previous studies evaluating stiff epidural catheters found that the three-holed design provided superior labour analgesia compared with an end-holed design. This was believed due to improved medication distribution. Recently, flexible epidural catheters with both designs have been shown to be superior to the stiff epidural catheters. We investigated the success of labour analgesia comparing the flexible three-holed with the flexible end-holed epidural catheter. This was a prospective, single-blinded randomized study. We enrolled 500 parturients in active labour. The primary outcome was complete relief of labour pain assessed at 30 min. We also assessed the occurrence of paresthesias, intravascular and intrathecal placement, catheter replacement, and treatment of breakthrough pain during labour. Comparisons were made using Pearson's chi(2), with significance determined at the 0.05 level. Four hundred and ninety-three subjects completed the study. Initial analgesia was similar (complete labour analgesia: end-holed=85% vs 80% 95% CI of difference: 13% to -3%; P=NS). The incidence of paresthesia was similar (end-holed=3.6% vs 5.3%; P=NS). There was one intrathecal and three intravascular catheters in the three-holed group and two intravascular catheters in the end-holed group. The number of supplemental boluses and catheter replacements required during labour was similar between the groups. There were no differences in the initial analgesia success rate, complications, or labour analgesia between end-hole vs multi-hole flexible epidural catheters.Keywords
This publication has 18 references indexed in Scilit:
- Uniport soft-tip, open-ended catheters versus multiport firm-tipped close-ended catheters for epidural labor analgesia: a quality assurance studyJournal of Clinical Anesthesia, 2000
- An in vitro evaluation of flow from multihole epidural catheters during continuous infusion with four different infusion pumpsAnaesthesia, 1999
- Epidural Catheter Tip Position and Distribution of Injectate Evaluated by Computed TomographyAnesthesiology, 1999
- Decreased incidence of complications in parturients with the Arrow (FlexTip Plus™) epidural catheterCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1998
- Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labourBritish Journal of Anaesthesia, 1997
- A Comparison of Multiport and Uniport Epidural Catheters in Laboring PatientsAnesthesia & Analgesia, 1997
- Superiority of multi-orifice over single-orifice epidural catheters for labor analgesia and cesarean deliveryJournal of Clinical Anesthesia, 1997
- COMPARISON OF COMPLICATIONS ASSOCIATED WITH SINGLE-HOLED AND MULTI-HOLED EXTRADURAL CATHETERSBritish Journal of Anaesthesia, 1990
- A comparison between open‐end (single hole) and closed‐end (three lateral holes) epidural cathetersAnaesthesia, 1989
- Differential flow from multihole epidural cathetersAnaesthesia, 1988