Spatio-Temporal Segmentation in 3-D Echocardiographic Sequences Using Fractional Brownian Motion
- 9 December 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2286-2296
Abstract
An important aspect for an improved cardiac functional analysis is the accurate segmentation of the left ventricle (LV). A novel approach for fully-automated segmentation of the LV endocardium and epicardium contours is presented. This is mainly based on the natural physical characteristics of the LV shape structure. Both sides of the LV boundaries exhibit natural elliptical curvatures by having details on various scales, i.e. exhibiting ${fractal-like}$ characteristics. The fractional Brownian motion (fBm), which is a non-stationary stochastic process, integrates well with the stochastic nature of ultrasound echoes. It has the advantage of representing a wide range of non-stationary signals and can quantify statistical local self-similarity throughout the time-sequence ultrasound images. The locally characterized boundaries of the fBm segmented LV were further iteratively refined using global information by means of second-order moments. The method is benchmarked using synthetic 3D+time echocardiographic sequences for normal and different ischemic cardiomyopathy, and results compared with state-of-the-art LV segmentation. Furthermore, the framework was validated against real data from canine cases with expert-defined segmentations and demonstrated improved accuracy. The fBm-based segmentation algorithm is fully automatic and has the potential to be used clinically together with 3D echocardiography for improved cardiovascular disease diagnosis.
Keywords
All Related Versions
Funding Information
- Fulbright Scholarship (G-1-00005)
This publication has 33 references indexed in Scilit:
- Left-ventricular epi- and endocardium extraction from 3D ultrasound images using an automatically constructed 3D ASMComputer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization, 2014
- Comparison of Image Patches Using Local Moment InvariantsIEEE Transactions on Image Processing, 2014
- Contour tracking in echocardiographic sequences via sparse representation and dictionary learningMedical Image Analysis, 2014
- Combining Multiple Dynamic Models and Deep Learning Architectures for Tracking the Left Ventricle Endocardium in Ultrasound DataIEEE Transactions on Pattern Analysis and Machine Intelligence, 2013
- Two-scale renormalization-group classification of diffusive processesPhysical Review E, 2012
- Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart AssociationJournal of the American Society of Echocardiography, 2002
- Three-dimensional modeling for functional analysis of cardiac images, a reviewIEEE Transactions on Medical Imaging, 2001
- Heterogeneity of the wall motion velocity pattern and regional left ventricular myocardial function in a normal population. A pulsed Doppler tissue quantitative study: José Azevedo MD, Miguel Garcia-Fernandez PhD, Mar Moreno PhD, Pablo Puerta RN, Esteban Torrecilla MD, Daniel SanRoman MD, Juan Luis Delcan PhD. Laboratorio de Ecocardiografia, Servicio de Cardiologia, Hospital General “Gregorio Marañon”, Madrid, EspañaJournal of the American Society of Echocardiography, 1996
- Significance of echocardiographic atrioventricular plane displacement for the evaluation of left ventricular filling and end-diastolic pressure in patients with coronary artery diseaseThe International Journal of Cardiovascular Imaging, 1995
- Fractional Brownian Motions, Fractional Noises and ApplicationsSIAM Review, 1968