Evaluation of decontamination methods of oral biofilms formed on screw-shaped, rough and machined surface implants: an ex vivo study
Open Access
- 22 April 2020
- journal article
- research article
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 6 (1) , 1-11
Abstract
To evaluate the effect of several representative decontamination methods of oral biofilms on different implant surfaces. Eleven participants wore a hard resin splint carrying 6 rough (GC Aadva® implant; 3.3-mm diameter, 8-mm length) or machined (not commercially available) surface implants for 4 days to accumulate dental plaque naturally on the titanium surfaces of the implants. Apart from surface roughness, the morphology of all implants was identical. After detaching the implants from the splints, the ability of the following decontamination methods—gauze soaked in saline (G), ultrasonic scaler (US), air abrasive (Air), rotary stainless steel instrument (Rot), and Er:YAG laser (Las)—to cleanse the contaminated implant surface for 1 min extra-orally was tested. The control (Cont) group did not receive any decontamination. Scanning electron microscopic (SEM) investigation of one participant’s samples was employed to examine the post-instrumented implant surface for qualitative analysis, and bacterial culture of the remaining 10 participants’ samples was performed to count the number of colony-forming units (CFU) for quantitative analysis. The experimental sequence was initially performed for the rough surface implants and then similarly repeated for the machined surface implants. Bacterial CFU counts among the six groups were analyzed using the Steel-Dwass test, and differences between rough and machined surface implants were determined using the Mann-Whitney U test. G and Rot eliminated most biofilms on machined surface implants according to SEM analysis. G, Air, and Rot removed significantly more of the biofilms on rough and machined surface implants compared with US according to CFU counts. Moreover, G significantly reduced more biofilms than Las on machined surface implants. The analysis between rough and machined surface implants showed that Cont, G, and US were better able to cleanse biofilms on machined surface implants compared with rough surface implants. Gauze soaked in saline and rotary stainless steel instruments may be advantageous for cleansing contaminated implant surfaces based on the qualitative and quantitative analyses. In contrast, air abrasives were not shown to be preferable in the qualitative analyses. Additionally, apart from the Er:YAG laser, the reduction of biofilms assessed in both qualitative and quantitative analyses demonstrated that all decontamination methods were better at cleansing machined surface implants compared with rough surface implants.Keywords
This publication has 41 references indexed in Scilit:
- In vitro efficacy of three different implant surface decontamination methods in three different defect configurationsClinical Oral Implants Research, 2019
- Prevalence of peri‐implant disease and risk indicators in a Japanese population with at least 3 years in function—A multicentre retrospective studyClinical Oral Implants Research, 2018
- Peri‐implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri‐Implant Diseases and ConditionsJournal of Periodontology, 2018
- Effect of cleansing of biofilm formed on titanium discsClinical Oral Implants Research, 2014
- Rotating titanium brush for plaque removal from rough titanium surfaces – an in vitro studyClinical Oral Implants Research, 2013
- Effects of 10 cleaning instruments on four different implant surfaces.2012
- Microbiologic Results After Non‐Surgical Erbium‐Doped:Yttrium, Aluminum, and Garnet Laser or Air‐Abrasive Treatment of Peri‐Implantitis: A Randomized Clinical TrialJournal of Periodontology, 2011
- Influence of different treatment approaches on non‐submerged and submerged healing of ligature induced peri‐implantitis lesions: an experimental study in dogsJournal of Clinical Periodontology, 2006
- Prevalence of subjects with progressive bone loss at implantsClinical Oral Implants Research, 2005
- Bactericidal Effect of the Er:YAG Laser on Dental Implant Surfaces: An In Vitro StudyJournal of Periodontology, 2002