Feasibility of Using Bluetooth Low Energy Beacon Sensors to Detect Magnifier Usage by Low Vision Patients
- 1 September 2018
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (9) , 844-851
Abstract
SIGNIFICANCE: We demonstrated proof of concept for the potential for Bluetooth low energy beacons to reliably collect data to serve as an indicator that low vision patients are using handheld magnifiers for reading, which might be used in the future to prevent the abandonment of magnification or other assistive devices. PURPOSE: Bluetooth low energy beacons are an emerging novel technology involving tiny sensors that collect real‐time, continuous, objective data, which might help to ascertain the abandonment of low vision devices in a timely manner, thus prompting a follow‐up evaluation to attempt to resolve issues. We evaluated whether Bluetooth beacon data could indicate when low vision patients used handheld optical magnifiers for reading. METHODS: We recorded temperature and/or relative humidity data from Estimote sticker and BlueMaestro Tempo Disc beacons attached to handles of optical magnifiers used for reading by low vision patients in clinic (n = 16) and at home (n = 3). RESULTS: In the clinic, patients whose hand/fingers made direct versus indirect contact with Estimote beacons had greater temperature increases on average from baseline after 30 seconds (0.73 ° C vs. 0.28 ° C), 60 seconds (1.04 ° C vs. 0.40 ° C), 90 seconds (1.39 ° C vs. 0.60 ° C), 105 to 120 seconds (1.59 ° C vs. 0.62 ° C), and 135 to 150 seconds (2.07 ° C vs. 0.97 ° C). During magnifier usage at home, BlueMaestro beacons measured rapidly increased temperature (5.6 ° C per minute on average; range 2.7 to 7.3 ° C) and relative humidity (19.4% per minute on average; range 8.7 to 34%). Humidity tended to reach its maximum increase and return back to baseline significantly more quickly than temperature ( P =. 007). All increases during magnifier usage were much greater than the maximum room fluctuations without use (clinic, 0.2 ° C over 120 seconds; home, 0.6 ° C and 2.4% over 1 minute). The beacons were nonintrusive and acceptable by patients. CONCLUSIONS: Estimote and BlueMaestro beacons can reliably detect temperature and/or humidity increases when held by low vision patients while reading with a magnifier.Keywords
This publication has 11 references indexed in Scilit:
- Proposal and Evaluation of BLE Discovery Process Based on New Features of Bluetooth 5.0Sensors, 2017
- eTEST: Developing a Smart Home HIV Testing Kit that Enables Active, Real-Time Follow-Up and Referral After TestingJMIR mHealth and uHealth, 2017
- Outcomes of the Veterans Affairs Low Vision Intervention Trial II (LOVIT II)JAMA Ophthalmology, 2017
- Opportunistic Sensor Data Collection with Bluetooth Low EnergySensors, 2017
- Think Like a HackerJournal of Diabetes Science and Technology, 2016
- Characterizing Functional Complaints in Patients Seeking Outpatient Low-Vision Services in the United StatesOphthalmology, 2014
- Smartphone, tablet computer and e‐reader use by people with vision impairmentOphthalmic and Physiological Optics, 2014
- Comparison of Clinician‐Predicted to Measured Low Vision OutcomesOptometry and Vision Science, 2013
- Baseline Traits of Low Vision Patients Served by Private Outpatient Clinical Centers in the United StatesArchives of Ophthalmology (1950), 2012
- Abandonment of Low‐Vision Devices in an Outpatient PopulationOptometry and Vision Science, 2011