Repeatability of Pentacam HR in Keratoconus According to Two Different Scan Protocols: 25-3D Scan and 50-Cornea Fine
Open Access
- 11 January 2025
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (2) , 439
Abstract
Background: This study aims to evaluate the repeatability of the Pentacam HR, comparing two different measurement modes (50-cornea fine and 25-3D scan) in patients affected by keratoconus. Methods: Multicenter retrospective study, conducted at Eye Clinic of the ASST-Spedali Civili-University of Brescia, Italy, and St. Paul’s Eye Unit, Royal Liverpool University Hospital, United Kingdom. A total of 72 eyes from 72 patients with keratoconus underwent six consecutive measurements, three using the 25-3D scan mode and three with the 50-Cornea fine mode. Measurements were made by one single observer, using the Scheimpflug corneal tomographer camera (Pentacam HR, Oculus, Wetzlar, Germany). Repeatability was assessed using the within-subject SD (Sw) statistic from a two-way analysis of variance. Results: Both measurement modes had excellent repeatability. The interclass coefficient correlation (ICC) was excellent (>0.9) in all the parameters evaluated, apart from anterior and posterior astigmatic axes and posterior astigmatism (ICC > 0.8) and index of height asymmetry (IHA) (ICC < 0.6). However, in 18 of 29 parameters, the ICC was higher in case of 25-3D scan. Repeatability limit for Kmax was 1.00D in 25-3D scan mode and 1.02D in case of 50-cornea fine. Conclusions: 25-3D scan may be preferable to 50-Cornea fine, in view of having slightly higher ICC in case of patients with keratoconus. Repeatability limits reported may be helpful in clinical practice for assessing the progression of keratoconus.Keywords
This publication has 23 references indexed in Scilit:
- Epithelium-on versus epithelium-off corneal collagen crosslinking for keratoconus: a systematic review and meta-analysisGraefe's Archive for Clinical and Experimental Ophthalmology, 2023
- Keratoconus: An updated reviewContact Lens and Anterior Eye, 2022
- Repeatability of the Pentacam HR in Various Grades of KeratoconusAmerican Journal of Ophthalmology, 2020
- Comparison of Anterior Chamber Depth between Normal and Keratoconic EyesJournal of Current Ophthalmology, 2020
- Pentacam Accuracy in Discriminating Keratoconus From Normal Corneas: A Diagnostic Evaluation StudyEye & Contact Lens: Science & Clinical Practice, 2019
- Repeatability and reliability of ectasia display and topometric indices with the Scheimpflug system in normal and keratoconic eyesJournal of Cataract & Refractive Surgery, 2018
- Efficacy of Corneal Collagen Cross-Linking for the Treatment of KeratoconusCornea, 2016
- Global Consensus on Keratoconus and Ectatic DiseasesCornea, 2015
- Reduced Precision of the Pentacam HR in Eyes with Mild to Moderate KeratoconusOphthalmology, 2015
- KeratoconusSurvey of Ophthalmology, 1998