Determination of cardiac output in neonatal foals by ultrasound velocity dilution and its comparison to the lithium dilution method
- 7 October 2009
- journal article
- Published by Wiley in Journal of Veterinary Emergency and Critical Care
- Vol. 19 (5) , 438-443
Abstract
Objective – To compare cardiac output (CO) measured by use of lithium dilution (LiDCO) and ultrasound velocity dilution (UDCO) in conditions of high, intermediate, and low CO in anesthetized foals.Design – Original prospective study.Setting – University teaching hospital.Animals – Six foals 1–3 days of age (38–45 kg).Interventions – Neonatal foals were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. The CO was measured by use of LiDCO and UDCO techniques. Measurements were obtained from each foal at baseline and during low, intermediate, and high CO states. Measurements were converted to cardiac index (cardiac index=CO/body weight) values for statistical analysis. Agreement between the 2 methods was determined using Bland and Altman analysis and concordance correlation coefficients.Measurements and Main Results – LiDCO determinations of CO ranged between 4.0 and 14.0 L/min resulting in cardiac index ranging between 75.5 and 310 mL/kg/min. There was no significant effect of blood pressure variation on bias or relative bias (P=0.62 and 0.93, respectively). The mean bias and relative bias of UDCO (±SD) compared with LiDCO were −20.1±39.2 mL/kg/min and −7.7±23.4%, respectively. Concordance correlation coefficient between LiDCO and UDCO was 0.833.Conclusions – When compared with LiDCO, the UDCO technique has acceptable clinical utility for measuring CO in healthy anesthetized newborn foals.Keywords
This publication has 29 references indexed in Scilit:
- Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients*Pediatric Critical Care Medicine, 2008
- Direct effects of volatile anesthetics on cardiac functionaPerfusion, 2008
- Noninvasive Measurement of Cardiac Output in Hemodialysis Patients by Task Force Monitor: A Comparison with the Transonic SystemASAIO Journal, 2007
- Effects of dobutamine, norepinephrine, and vasopressin on cardiovascular function in anesthetized neonatal foals with induced hypotensionAmerican Journal of Veterinary Research, 2006
- Comparing different methods of cardiac output determinationEuropean Journal of Anaesthesiology, 2006
- Cardiac Output Measurement by Partial Carbon Dioxide Rebreathing, 2-Dimensional Echocardiography, and Lithium-Dilution Method in Anesthetized Neonatal FoalsJournal of Veterinary Internal Medicine, 2005
- Cardiac Output Technologies with Special Reference to the HorseJournal of Veterinary Internal Medicine, 2003
- Novel Method to Measure Access Flow During Hemodialysis by Ultrasound Velocity Dilution TechniqueASAIO Journal, 1995
- Theory and validation of access flow measurement by dilution technique during hemodialysisKidney International, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986