Effect of Timings of the Lavare Cycle on the Ventricular Washout in an In Vitro Flow Visualization Setup
- 16 February 2021
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (5) , 517-528
Abstract
Left ventricular assist devices inherently alter the intraventricular flow field and create areas of blood stasis with potential thrombus formation. The Lavare cycle of the Medtronic HeartWare HVAD was designed to improve ventricular washout. This study aims to evaluate its effects on ventricular washout in a pulsatile in vitro setting with a focus on the timing of pump speed changes. Ventricular flow fields were obtained via particle image velocimetry in two modes: With constant left ventricular assist devices speed and with the Lavare cycle applied. The start of the Lavare cycle was shifted over an entire cardiac cycle, and ventricular washout was evaluated based on velocity fields, kinetic energy, and normalized pulsatility of flow fields. The ventricular flow fields showed dependence on the timing of the Lavare cycle and interaction between speed changes and the cardiac phase. Higher apical velocity was observed for speed decreases at the late E wave and for increases at mid systole by 29% (P = 0.002) and 61% (P < 0.001), respectively. Mean apical kinetic energy for these phases also increased by 21% (P = 0.0013) and 46% (P < 0.001). The Lavare cycle generally promotes higher apical washout and can specifically generate further improved washout if speed steps are applied at the correct timing on the cardiac cycle.Keywords
This publication has 40 references indexed in Scilit:
- Programmed Speed Reduction Enables Aortic Valve Opening and Increased Pulsatility in the LVAD-Assisted HeartASAIO Journal, 2015
- The Clinical Assessment of Intraventricular FlowsAnnual Review of Fluid Mechanics, 2015
- Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failureThe Journal of Heart and Lung Transplantation, 2015
- Computational analysis of the importance of flow synchrony for cardiac ventricular assist devicesComputers in Biology and Medicine, 2014
- An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trialThe Journal of Heart and Lung Transplantation, 2014
- Thromboembolism Is Linked to Intraventricular Flow Stasis in a Patient Supported with a Left Ventricle Assist DeviceASAIO Journal, 2013
- Fixation and Mounting of Porcine Aortic Valves for use in Mock CircuitsThe International Journal of Artificial Organs, 2013
- Asymmetric speed modulation of a rotary blood pump affects ventricular unloadingEuropean Journal of Cardio-Thoracic Surgery, 2012
- The Role of Echocardiography and Other Imaging Modalities in Patients With Left Ventricular Assist DevicesJACC: Cardiovascular Imaging, 2010
- Design Concepts and Principle of Operation of the HeartWare Ventricular Assist SystemASAIO Journal, 2010