Testing and analysis of infilled reinforced concrete frames strengthened with CFRP reinforcement
- 1 October 2011
- journal article
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 30 (19) , 1605-1620
Abstract
There is an excessive demand for the rehabilitation of frame-type RC buildings which do not satisfy current seismic code provisions. Therefore, it is imperative to develop user-friendly strengthening methodologies which do not necessitate the evacuation of the building during rehabilitation period. The aim of this study was to strengthen the masonry infill walls by means of diagonal carbon fiber-reinforced polymer fabrics and to integrate them with the existing structural frame in order to form a new lateral load resisting system. This study investigated the possible effects of height-to-width ratio of the infills on the overall behavior attained by the previously developed rehabilitation methodology. In the first part of the study, eight 1/3 scaled, one-bay, two-story RC frames with two different aspect ratios were tested. The experimental results in terms of lateral stiffness, strength, drift, and energy dissipation characteristics of the specimens were discussed. In the second part, a numerical study of the frames was conducted to estimate the non-linear behavior of the specimens.Keywords
This publication has 12 references indexed in Scilit:
- Performance of alternative CFRP retrofitting schemes used in infilled RC framesConstruction and Building Materials, 2010
- Analysis and design of FRP composites for seismic retrofit of infill walls in reinforced concrete framesComposites Part B: Engineering, 2007
- Analysis of reinforced concrete columns retrofitted with fiber reinforced polymer laminaComposites Part B: Engineering, 2007
- An experimental study on two different strengthening techniques for RC framesEngineering Structures, 2006
- TENSILE CAPACITIES OF CFRP ANCHORS2006
- CFRP OVERLAYS IN STRENGTHENING OF FRAMES WITH COLUMN REBAR LAP SPLICE PROBLEM2006
- Seismic assessment of an industrial frame structure designed according to Eurocodes. Part 2: Capacity and vulnerabilityEngineering Structures, 2005
- Seismic Retrofit of Concrete-Masonry-Infilled Steel Frames with Glass Fiber-Reinforced Polymer LaminatesJournal of Structural Engineering, 2004
- Strengthening of Masonry Structures Using Epoxy-Bonded FRP LaminatesJournal of Composites for Construction, 1998
- 5. Retrofit of Non‐Ductile Moment‐Resisting Frames Using Precast Infill Wall PanelsEarthquake Spectra, 1996