Study on the interzonal migration of airborne infectious particles in an isolation ward using benign bacteria
- 23 June 2012
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 23 (2) , 148-161
Abstract
Negative pressure isolation wards are essential infection control facilities against airborne transmissible diseases. Airborne infectious particles are supposed to be contained in the isolation room. However, negative pressure may break down by door-opening action or by human movement. Understanding the interzonal transport of airborne infectious particles in the isolation wards can aid the design and operation strategy of isolation facilities. In this work, the interzonal migration of airborne infectious particles by human movement was studied experimentally in an isolation ward. Artificial saliva solution with benign E. coli bacteria was aerosolized to simulate bacterium-laden infectious particles. The interzonal migration of aerosolized bacteria was characterized by biological air sampling. Less than 1% of airborne infectious particles were transported to the higher pressure zone when door was closed. With human movement, 2.7% of the particles were transported from the anteroom to the corridor. From high-to-low pressure zones, as much as 20.7% of airborne infectious particles were migrated. Only a minimal amount of particles was transported from the corridor to the positive pressure nurses’ station. Infection risk of tuberculosis of the healthcare workers and other occupants in the isolation wards were also assessed based on the measured migration ratios. Practical Implications Human movement is an important factor governing interzonal migration. It is the main cause of migration of airborne infectious particles to a relatively negative pressure zone. This study provides a set of experimentally obtained particle migration ratios by human movement. Other than serving as empirical data for further studies on the mechanics, these migration ratios can also be used to assess the infection risk for occupants in the isolation ward.Keywords
This publication has 33 references indexed in Scilit:
- Effectiveness of facemasks to reduce exposure hazards for airborne infections among general populationsJournal of The Royal Society Interface, 2011
- Norovirus, gastroenteritis, and indoor environmental qualityIndoor Air, 2011
- Movement of airborne contaminants in a hospital isolation roomJournal of The Royal Society Interface, 2009
- Evaluation of the effectiveness of commercially available contact plates for monitoring microbial environmentsLetters in Applied Microbiology, 2009
- 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care SettingsAmerican Journal of Infection Control, 2007
- Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable PathogensJournal of Occupational and Environmental Hygiene, 2005
- Containment testing of isolation roomsJournal of Hospital Infection, 2004
- A Combined Fluorochrome Method for Quantitation of Metabolically Active and Inactive Airborne BacteriaAerosol Science and Technology, 1999
- Air Volume Migration from Negative Pressure Isolation Rooms during Entry/ExitApplied Occupational and Environmental Hygiene, 1998
- Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert ParticlesAIHA Journal, 1998