Skin reactions in continuous glucose monitoring system users and their influence on adherence to therapy
Open Access
- 10 October 2026
- journal article
- Published by Remedium, Ltd. in Meditsinskiy sovet = Medical Council
- No. 14,p. 34-41
Abstract
Introduction. Continuous glucose monitoring (CGM) systems have become an integral component of type 1 diabetes mellitus therapy. However, their widespread adoption has revealed an underestimated problem: skin reactions, which serve as a significant barrier to consistent device usage. Aim. To assess the prevalence and structure of skin reactions associated with CGM use, perform differential diagnosis of dermatitis types, and identify factors influencing patient adherence to this technology. Mat erials and methods. The study included 75 pediatric patients with type 1 diabetes mellitus using CGM systems. Demographic data, duration of device usage, and characteristics of skin manifestations were analyzed. Results. The mean age of participants was 13.1 ± 3.5 years, with a mean CGM usage duration of 7.5 ± 2.7 months. Skin reactions were observed in 18 patients (24.0%). Simple contact dermatitis predominated, affecting 12 patients (66.7% of those with reactions; 16.0% of the total cohort). Allergic contact dermatitis was diagnosed in 6 patients (33.3%; 8.0%). All 12 patients (100%) with simple contact dermatitis continued CGM use despite symptoms. In contrast, adherence in the allergic dermatitis group was significantly lower: 5 out of 6 patients (83.3%) discontinued CGM due to intense pruritus and worsening skin conditions upon reapplication. Only one patient (16.7%) maintained adherence by employing pharmacological treatment and rotating sensor insertion sites. Conclusions. Skin reactions occur in 24.0% of CGM users, confirming the clinical significance of this issue. Simple contact dermatitis is twice as common as allergic contact dermatitis, follows a benign course, and does not compromise treatment adherence. Conversely, allergic contact dermatitis is a key factor leading to technology abandonment. These findings underscore the necessity for timely diagnosis and the development of personalized management strategies to ensure continued access to CGM therapy.Keywords
This publication has 26 references indexed in Scilit:
- Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full reviewContact Dermatitis, 2024
- Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full reviewContact Dermatitis, 2024
- New device, ‘old’ allergens. Allergic contact dermatitis caused by the Dexcom G7 glucose sensorContact Dermatitis, 2024
- High incidence of skin reactions secondary to the use of adhesives in glucose sensors or insulin pumps for the treatment of children with type 1 diabetesDiabetes Research and Clinical Practice, 2023
- A Toddler with Systemic Contact Dermatitis Caused by Diabetes DevicesSkin Health and Disease, 2023
- Prevalence and Description of the Skin Reactions Associated with Adhesives in Diabetes Technology Devices in an Adult Population: Results of the CUTADIAB StudyDiabetes Technology & Therapeutics, 2023
- A Comparison of Topical Corticosteroids and Topical Calcineurin Inhibitors for the Treatment of Atopic DermatitisThe Journal of Allergy and Clinical Immunology: In Practice, 2023
- Changes in adhesive ingredients in continuous glucose monitoring systems may induce new contact allergy patternContact Dermatitis, 2021
- Preserving Skin Integrity with Chronic Device Use in DiabetesDiabetes Technology & Therapeutics, 2018
- Change in skin properties over the first 10 years of life: a cross-sectional studyArchives of Dermatological Research, 2017