Radionuclide Bone Imaging as a Means of Differentiating Loosening and Infection in Patients with a Painful Total Hip Prosthesis
Authors:
- Brian R. J. WilliamsonBWBrian R. J. Williamson
- Robert E. McLaughlinRMRobert E. McLaughlin
- Gwo-Jaw WangGWGwo-Jaw Wang
- Charles W. MillerCMCharles W. Miller
- C. David TeatesCTC. David Teates
- Stuart T. BraySBStuart T. Bray
- 1 December 1979
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 133 (3) , 723-725
Abstract
Twenty patients with 23 painful total hip prostheses were examined by radionuclide imaging (20 cases), arthrography (11 cases), needle aspiration (9 cases) and surgery (19 cases) for the purpose of assessing loosening and/or infection. Bone imaging was most accurate, showing 3 main distribution of activity: ectopic calcification; focal increased activity at the upper and lower ends of the femoral prosthesis; and diffuse activity. Infection and loosening can be differentiated in many instances. None of the patients with focal activity had infection, compared to 2 of the 3 patients with diffuse uptake.Keywords
This publication has 3 references indexed in Scilit:
- Radiography, Radionuclide Imaging, and Arthrography in the Evaluation of Total Hip and Knee ReplacementRadiology, 1978
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- 99Tcm-diphosphonate scanning as an aid to diagnosis of infection in total hip joint replacementsBritish Journal of Radiology, 1977