Evaluation of the iTClamp 50 in a human cadaver model of severe compressible bleeding
Authors:
- Dennis FilipsDFDennis Filips
- Sarvesh LogsettySLSarvesh Logsetty
- Ian AtkinsonIAIan Atkinson
- 1 March 2014
- journal article
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 76 (3) , 791-797
Abstract
Uncontrolled hemorrhage is a significant cause of preventable death. The iTClamp 50 is a temporary wound closure device designed to control bleeding within seconds of an injury. This study evaluates the ability of the iTClamp to control compressible bleeding in a human cadaver model. Sterile water was pumped through the major arteries to mimic blood flow. Full-thickness, elliptical segments of skin were excised; arteriotomies or complete transections were performed on the major arteries in the thigh (distal femoral), groin (common femoral), neck (carotid), and arm (brachial). Scalp wounds were created by making a 4.4-cm linear incision to the level of the bone. Fluid losses from the wounds were compared with and without the iTClamp applied and with and without movement of the cadaver. Angiographic images of pressure-injected contrast were obtained of the neck and groin wounds. Hematoma volumes and needle penetration depth into the skin were measured. In all wounds tested, application of the iTClamp significantly reduced fluid loss in all wounds studied (p < 0.05), and movement of the cadaver did not affect the function of the iTClamp. For example, in one groin wound, the average fluid loss during 1 minute was reduced from 728.4 ± 79.3 mL to 5.6 ± 3.4 mL. Distal flow was maintained during application of the iTClamp, as illustrated in angiographic images obtained of the iTClamp applied to the neck and groin wounds. The average needle penetration depth into the skin was 4.21 ± 0.02 mm; furthermore, the iTClamp did not cause any visible skin damage or skin tearing. The iTClamp is effective at controlling fluid loss from open wounds within multiple compressible areas. The iTClamp does not occlude distal flow, and aside from small needle punctures, there was no other visible skin damage or skin tearing.Keywords
This publication has 26 references indexed in Scilit:
- The iTClamp Controls Junctional Bleeding in a Lethal Swine Exsanguination ModelPrehospital Emergency Care, 2013
- Procoagulant Activity in Hemostasis and ThrombosisAnesthesia & Analgesia, 2012
- Military Application of Tranexamic Acid in Trauma Emergency Resuscitation (MATTERs) StudyArchives of Surgery, 2012
- Early coagulopathy in trauma patients: An on-scene and hospital admission studyInjury, 2012
- Died of Wounds on the Battlefield: Causation and Implications for Improving Combat Casualty CareJournal of Trauma: Injury, Infection & Critical Care, 2011
- Survival With Emergency Tourniquet Use to Stop Bleeding in Major Limb TraumaAnnals of Surgery, 2009
- QuikClot Use in Trauma for Hemorrhage Control: Case Series of 103 Documented UsesJournal of Trauma: Injury, Infection & Critical Care, 2008
- Impact of Hemorrhage on Trauma Outcome: An Overview of Epidemiology, Clinical Presentations, and Therapeutic ConsiderationsJournal of Trauma: Injury, Infection & Critical Care, 2006
- Early Coagulopathy Predicts Mortality in Trauma2003
- Lethal Injuries and Time to Death in a Level I Trauma Center 1 1The views expressed in this article are those of the author(s) and do not reflect the official policy or position of the Department of the Navy, Department of Defense, nor the U.S. Government.Journal of the American College of Surgeons, 1998