The shapes and sizes of two domains of tropomodulin, the P‐end‐capping protein of actin‐tropomyosin
Authors:
- Tetsuro FujisawaTFTetsuro Fujisawa
- Alla KostyukovaAKAlla Kostyukova
- Yuichiro MaédaYMYuichiro Maéda
- 30 May 2001
- journal article
- Published by Wiley in FEBS Letters
- Vol. 498 (1) , 67-71
Abstract
Tropomodulin, the P‐end (slow‐growing end)‐capping protein of the actin‐tropomyosin filament, and its fragment (C20) of the C‐terminal half were studied by synchrotron small‐angle X‐ray scattering, restoring low‐resolution shapes using an ab initio shape‐determining procedure. Tropomodulin is elongated (115 Å long) and consists of two domains, one of 65 Å in length and the other being similar to C20 in shape and size if the long axes of the two are tilted by about 40° relative to each other. We propose a model for tropomodulin in association with tropomyosin and actin: the N‐terminal half of tropomodulin, a rod, binds to the N‐terminus of tropomyosin and the C‐terminal triangle domain protrudes from the P‐end being slightly bent towards the actin subunit at the end, thereby blocking the P‐end.Keywords
This publication has 21 references indexed in Scilit:
- Small-angle X-ray scattering station at the SPring-8 RIKEN beamlineJournal of Applied Crystallography, 2000
- Tropomodulin-Binding Site Mapped to Residues 7–14 at the N-Terminal Heptad Repeats of Tropomyosin Isoform 5Archives of Biochemistry and Biophysics, 2000
- The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detectorJournal of Synchrotron Radiation, 1999
- Identification of a Novel Tropomodulin Isoform, Skeletal Tropomodulin, That Caps Actin Filament Pointed Ends in Fast Skeletal MuscleJournal of Biological Chemistry, 1999
- Restoring Low Resolution Structure of Biological Macromolecules from Solution Scattering Using Simulated AnnealingBiophysical Journal, 1999
- DEFINING ACTIN FILAMENT LENGTH IN STRIATED MUSCLE: Rulers and Caps or Dynamic Stability?Annual Review of Cell and Developmental Biology, 1998
- Large-aperture TV detector with a beryllium-windowed image intensifier for x-ray diffractionReview of Scientific Instruments, 1995
- A direct indirect method of small-angle scattering data treatmentJournal of Applied Crystallography, 1993
- Small-angle-scattering-data treatment by the regularization methodActa Crystallographica Section A Foundations of Crystallography, 1988
- Small-angle scattering. Information content and error analysisJournal of Applied Crystallography, 1980