Purpose: This study investigated kinetic lipid uptake to four silicone hydrogel (SiHy) lenses over a period of four weeks, using an in-vitro radiolabel method. Methods: Four contemporary monthly replacement SiHy lenses (lotrafilcon B, senofilcon C, comfilcon A, samfilcon A) were incubated in three different solutions: 1) An artificial tear solution (ATS) containing 14C-labeled phosphatidylcholine (PC), 2) an ATS containing 14C-cholesteryl oleate (CO) and 3) an ATS containing four 14C-radiolabeled lipids (PC, phosphatidylethanolamine, CO, and cholesterol (total lipid)). After 16 hours, lipids were extracted twice from the lenses with chloroform:methanol and the radioactive counts determined the lipid quantities to simulate 1 day of wear. OPTI-FREE PureMoist (Alcon) was used to clean and disinfect the remaining lenses daily and the lipid quantities were further determined after 2 weeks and 4 weeks. Results: The amount of total lipid increased for all lenses over time (p<0.01). After four weeks, total lipid accumulated was 20.26 ± 0.15 µg/lens for senofilcon C, which was significantly higher (p<0.01) than all other lens materials (samfilcon A - 17.84±0.21; comfilcon A - 16.65 ± 0.12; lotrafilcon B - 7.41 ± 0.56 µg/lens). CO was highest on lotrafilcon B (1.26±0.13µg/lens) and senofilcon C attracted the most PC (3.95 ± 0.12 µg/lens) compared to the other materials. Conclusion: The amount of both polar and non-polar lipid deposition on monthly replacement SiHy lenses increased over 4 weeks, with significant differences being seen between lens materials.Keywords
Funding Information
- Johnson and Johnson Vision Care, Inc. (N/A)
This publication has 42 references indexed in Scilit:
- Human Tear Fluid Lipidome: From Composition to FunctionPLOS ONE, 2011
- In Vitro Analysis of the Physical Properties of Contact Lens Blister Pack SolutionsOptometry and Vision Science, 2011
- In Vitro Lipid Deposition on Hydrogel and Silicone Hydrogel Contact LensesInvestigative Ophthalmology & Visual Science, 2010
- Contact Lens Deposits, Adverse Responses, and Clinical Ocular Surface ParametersOptometry and Vision Science, 2010
- Biochemical analyses of lipids deposited on silicone hydrogel lensesJournal of Optometry, 2010
- Kinetics of Lysozyme Activity Recovered from Conventional and Silicone Hydrogel Contact Lens MaterialsJournal of Biomaterials Science, Polymer Edition, 2010
- Understanding and Analyzing Meibomian Lipids—A ReviewCurrent Eye Research, 2008
- Lipid Deposition on Hydrogel Contact Lenses: How History Can Help Us TodayOptometry and Vision Science, 2007
- Tear Film, Contact Lens, and Patient-Related Factors Associated with Contact Lens–Related Dry EyeInvestigative Ophthalmology & Visual Science, 2006
- Spoliation and Clinical Performance of Monthly vs. Three Monthly Group II Disposable Contact LensesOptometry and Vision Science, 1996