Gait Analysis After Intertrochanteric Hip Fracture: Does Shortening Result in Gait Impairment?
Authors:
- 1 November 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 32 (11) , 554-558
Abstract
Objective: To determine the association between fracture collapse with altered gait after intertrochanteric (IT) fracture using the trochanteric fixation nail (TFN) and helical blade. Design: Prospective cohort study. Setting: Academic Level I trauma center. Patients: Seventy-two patients with IT hip fractures (OTA/AO 31) treated between 2012 and 2016. The average age was 79.7 years (range, 51–94 years); there were 59 women and 13 men. Intervention: All patients were treated with cephalomedullary nailing using the TFN (DePuy-Synthes, West Chester, PA) with a helical blade. Main Outcome Measures: At follow-up appointments, temporospatial gait parameters were measured and recorded. Radiographs were analyzed at the time of surgery and at each follow-up visit. Amount of radiographic femoral neck shortening was measured radiographically. Patients completed the Harris Hip Score, visual analog scale for pain, Short Form-36 Physical Component Score, and Short Form-36 Mental Component Score. Results: The mean length of follow-up between the surgery and the gait analysis was 8.6 months (±0.7 months). The mean amount of shortening was 4.7 mm (±0.6 mm). Out of the 72 patients analyzed, there were 15 patients (20.8%) who shortened more than 8 mm, 7 patients (9.7%) who shortened 10 mm or more, and 2 patients (2.8%) who shortened more than 20 mm. Mean shortening was 3.0 mm for stable OTA/AO 31-A1 fractures, whereas the unstable patterns (OTA/AO 31-A2, 31-A3) demonstrated a mean shortening of 5.9 mm (P = 0.02). There was significant correlation between increased shortening and decreased cadence (P = 0.008), increased double support time (P < 0.001), decreased step length (P = 0.001), and increased single support asymmetry (P = 0.04) during gait analysis. The threshold of 8 mm of shortening predicted decreased cadence (P = 0.008), increased double support time (P < 0.001), and decreased step length (P = 0.006). Analysis of patient-reported outcome scores, including the Harris Hip Score, visual analog scale, SF-36 Physical Component Score, and SF-36 Mental Component Score, revealed no significant association with shortening. Conclusions: Results from this study indicate that shortening after cephallomedullary nailing of IT hip fractures using the TFN with a helical blade is associated with altered gait, specifically decreased cadence, increased double support time, decreased step length, and increased single support time asymmetry. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 19 references indexed in Scilit:
- Presence of a Nail in the Medullary Canal; Is It Enough to Prevent Femoral Neck Shortening in Trochanteric Fracture?Yonsei Medical Journal, 2014
- Catastrophic Failure After Open Reduction Internal Fixation of Femoral Neck Fractures With a Novel Locking Plate ImplantJournal of Orthopaedic Trauma, 2012
- Functional and Radiographic Outcomes of Intertrochanteric Hip Fractures Treated With Calcar Reduction, Compression, and Trochanteric Entry NailingJournal of Orthopaedic Trauma, 2012
- Femoral Neck Shortening and Varus Collapse After Navigated Fixation of Intracapsular Femoral Neck FracturesJournal of Orthopaedic Trauma, 2012
- Walk ratio (step length/cadence) as a summary index of neuromotor control of gaitInternational Journal of Rehabilitation Research, 2011
- Normative spatiotemporal gait parameters in older adultsGait & Posture, 2011
- The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hipThe Journal of Bone and Joint Surgery. British volume, 2008
- Femoral Shortening After Surgical Treatment of Trochanteric Fractures in Nongeriatric PatientsJournal of Trauma: Injury, Infection & Critical Care, 2008
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- An evaluation of accuracy and repeatability of a novel gait analysis deviceArchives of orthopaedic and trauma surgery, 2006