Signal-to-noise ratio in diffusion-ordered spectroscopy: how good is good enough?
Open Access
- 6 October 2021
- journal article
- research article
- Published by Copernicus GmbH in Magnetic Resonance
- Vol. 2 (2) , 733-739
Abstract
Diffusion-ordered NMR spectroscopy (DOSY) constructs multidimensional spectra displaying signal strength as a function of Larmor frequency and of diffusion coefficient from experimental measurements using pulsed field gradient spin or stimulated echoes. Peak positions in the diffusion domain are determined by diffusion coefficients estimated by fitting experimental data to some variant of the Stejskal–Tanner equation, with the peak widths determined by the standard error estimated in the fitting process. The accuracy and reliability of the diffusion domain in DOSY spectra are therefore determined by the uncertainties in the experimental data and thus in part by the signal-to-noise ratio of the experimental spectra measured. Here the Cramér–Rao lower bound, Monte Carlo methods, and experimental data are used to investigate the relationship between signal-to-noise ratio, experimental parameters, and diffusion domain accuracy in 2D DOSY experiments. Experimental results confirm that sources of error other than noise put an upper limit on the improvement in diffusion domain accuracy obtainable by time averaging.Keywords
All Related Versions
Funding Information
- Engineering and Physical Sciences Research Council (EP/N033949/1, EP/R018790/1)
This publication has 27 references indexed in Scilit:
- Diffusion-Ordered Spectroscopy (DOSY)2007
- Biexponential Fitting of Diffusion-Ordered NMR Data: Practicalities and LimitationsAnalytical Chemistry, 2006
- Optimization of diffusion measurements using Cramer‐Rao lower bound theory and its application to articular cartilageMagnetic Resonance in Medicine, 2003
- Relaxation-Assisted Separation of Chemical Sites in NMR Spectroscopy of Static SolidsJournal of the American Chemical Society, 2003
- A one‐shot sequence for high‐resolution diffusion‐ordered spectroscopyMagnetic Resonance in Chemistry, 2002
- Diffusion ordered nuclear magnetic resonance spectroscopy: principles and applicationsProgress in Nuclear Magnetic Resonance Spectroscopy, 1999
- Reference deconvolution methodsProgress in Nuclear Magnetic Resonance Spectroscopy, 1997
- Systematic sources of signal irreproducibility and t1 noise in high-field NMR spectrometersJournal of Magnetic Resonance (1969), 1992
- Sources of t1 noise in two-dimensional NMRJournal of Magnetic Resonance (1969), 1984
- Molecular self-diffusion coefficients in Fourier transform nuclear magnetic resonance spectrometric analysis of complex mixturesAnalytical Chemistry, 1981