Multi-Objective Optimization of Bioresorbable Magnesium Alloy Stent by Kriging Surrogate Model
Authors:
- 12 April 2022
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 13 (6) , 829-839
Abstract
Purpose The study proposed a multi-objective optimization method based on Kriging surrogate model and finite element analysis to mitigate the redial recoil and foreshortening ratio of bioresorbable magnesium alloy stent, and investigate the impact of strut thickness on stent expansion behavior. Methods Finite element analysis have been carried out to compare the expansion behavior of stents with various strut thickness. Latin hypercube sampling (LHS) was adopted to generate train sample points in the design space, and the Kriging surrogate model was constructed between strut parameters and stent behavior. The genetic algorithm (GA) was employed to find the optimal solution in the global design space. Results Stents with thinner struts experience lower stress but suffer from severe radial recoil and foreshortening effects. The radial recoil is decreased by 66%, and foreshortening ratio is reduced by 60% for the optimized stent with U-bend width 90.7 \(\upmu{\text{m}}\) and link width 77.9 \(\upmu{\text{m}}\). The errors between Kriging surrogate model and finite element simulation are 6% and 9% for the radial recoil and foreshortening ratio. Conclusion Stent expansion behavior are highly dependent on design parameters, i.e. thickness, U-bend and link strut width. The purposed Multi-objective optimization approach based on Kriging surrogate model and finite element analysis is efficient in stent design optimization problem.
Keywords
Funding Information
- National Natural Science Foundation of China (51905037)
This publication has 25 references indexed in Scilit:
- Current Status of Bioresorbable Scaffolds in the Treatment of Coronary Artery DiseaseJACC, 2014
- Impact of stent strut design in metallic stents and biodegradable scaffoldsInternational Journal of Cardiology, 2014
- Computational analysis of the radial mechanical performance of PLLA coronary artery stentsMedical Engineering & Physics, 2014
- Optimizing the design of a bioabsorbable metal stent using computer simulation methodsBiomaterials, 2013
- Optimization based simulation of self-expanding Nitinol stentMaterials & Design (1980-2015), 2013
- Coronary stents: historical development, current status and future directionsBritish Medical Bulletin, 2013
- Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trialThe Lancet, 2013
- Application of Mg-based alloys for cardiovascular stentsInternational Journal of Biomedical Engineering and Technology, 2013
- Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trialThe Lancet, 2007