Communication. Rapid sample preconcentration by aerosol deposition for the determination of trace elements by inductively coupled plasma spectrometry
Authors:
- Robin RattrayRRRobin Rattray
- Jorge MiñosoJMJorge Miñoso
- Eric D. SalinESEric D. Salin
- 1 January 1993
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 8 (7) , 1033-1036
Abstract
A new approach to sample preconcentration for inductively coupled plasma spectrometry has been developed. The method involves deposition of the sample solution as an aerosol into an inductively heated, graphite, direct sample insertion probe. With a deposition time of 2 min and a sample volume of 0.5 ml, detection limits for Cu, Zn, Cd and Pb were 0.05, 0.12, 0.10, and 0.07 ppb, respectively. These limits represent an improvement of almost three orders of magnitude over those obtained by conventional sample introduction in the same system. The relative standard deviation was <5% at the 10 ppb level. The conditions used and some performance characteristics are presented and discussed.Keywords
This publication has 9 references indexed in Scilit:
- Differential determination of chromium(VI) and total chromium in natural waters using flow injection on-line separation and preconcentration electrothermal atomic absorption spectrometryThe Analyst, 1992
- Flow Injection Preconcentration Coupled with Direct Sample Insertion for Inductively Coupled Plasma Atomic Emission SpectrometryApplied Spectroscopy, 1991
- Flame Atomic Absorption Spectrometric Determination of Cadmium, Cobalt, and Nickel in Biological Samples Using a Flow Injection System with On-Line Preconcentration by Co-Precipitation without FiltrationApplied Spectroscopy, 1991
- Evaluation of a modified commercial graphite furnace for reduction of isobaric interferences in argon inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Elimination of some spectral interferences and matrix effects in inductively coupled plasma-mass spectrometry using direct sample insertion techniquesSpectrochimica Acta Part B: Atomic Spectroscopy, 1989
- Introduction of liquid samples into the inductively coupled plasma by direct insertion on a wire loopAnalytical Chemistry, 1989
- Elements of Induction Heating1988
- Discrete nebulization using aerosol deposition in electrothermal vaporization for inductively coupled plasma-atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- Coulometric study of the redox dynamics of iron in seawaterAnalytical Chemistry, 1984