A Targeted Review of Study Outcomes With Short (≤7 mm) Endosseous Dental Implants Placed in Partially Edentulous Patients
Authors:
- D.A. DeporterDDD.A. Deporter
- R.M. PilliarRPR.M. Pilliar
- T. ArenovichTAT. Arenovich
- 1 June 2004
- journal article
- review article
- Published by Wiley in Journal of Periodontology
- Vol. 75 (6) , 798-804
Abstract
Background: Generally, threaded root‐form endosseous dental implants are thought to perform poorly in short lengths (i.e., 7 mm; 2) data separable into maxillary versus mandibular results; 3) criteria for “failure” clearly defined; and 4) minimal functional period of 2 years.Results: Twelve papers were identified as follows: eight with machined threaded implants, two with acid‐treated threaded implants, and two with sintered porous‐surfaced press‐fit implants. The following results were found: 1) machined surface implants experienced greater failure rates than textured surface implants; 2) with the exception of sintered porous‐surfaced implants, 7 mm long dental implants appear to have higher failure rates than those >7 mm length; and 3) with textured surface implants, higher failure rates were more likely in the maxilla than in the mandible, but with machined surface implants there were no differences in failure rates between maxilla and mandible.Conclusions: Dental implant surface geometry is a major determinant in how well these implants perform in short lengths, defined here as lengths of ≤7 mm. While threaded implants show higher failure rates in short versus longer lengths, sintered poroussurfaced implants perform well in the defined “short” lengths. More studies are needed to better assess the performance of short, acid‐washed threaded implants. J Periodontol 2004;75:798‐804.Keywords
This publication has 14 references indexed in Scilit:
- Ten‐Year Results of a Prospective Study Using Porous‐Surfaced Dental Implants and a Mandibular OverdentureClinical Implant Dentistry and Related Research, 2002
- Biologic outcome of implant‐supported restorations in the treatment of partial edentulismClinical Oral Implants Research, 2002
- A Multi‐Center Study Comparing Dual Acid‐Etched and Machined‐Surfaced Implants in Various Bone QualitiesJournal of Periodontology, 2001
- A Comparison of Endosseous Dental Implant SurfacesJournal of Periodontology, 1999
- Overview of Surface Variability of Metallic Endosseous Dental ImplantsImplant Dentistry, 1998
- The peri‐implant hard and soft tissues at different implant systems. A comparative study in the dog.Clinical Oral Implants Research, 1996
- Fixture design and overload influence marginal bone loss and future success in the Brånemark® systemClinical Oral Implants Research, 1992
- A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulismThe Journal of Prosthetic Dentistry, 1992
- Finite element analysis of six endosseous implantsThe Journal of Prosthetic Dentistry, 1990
- Osseous adaptation to continuous loading of rigid endosseous implantsAmerican Journal of Orthodontics, 1984