A Multicenter, Open-Label, Single-Arm Phase I Trial of Dual-Wield Parenchymal Transection: A New Technique of Liver Resection Using the Cavitron Ultrasonic Surgical Aspirator and Water-Jet Scalpel Simultaneously (HiSCO-14 Trial)
Authors:
Open Access
- 18 November 2023
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 15 (11) , e49028
Abstract
Purpose: This study evaluated the safety and feasibility of a technique of liver resection named dual-wield parenchymal transection technique (DWT), using cavitron ultrasonic surgical aspirator (CUSA) and water-jet scalpel simultaneously. Methods: This multicenter, prospective, open-label, and single-arm phase I trial included patients aged 20 years or older with hepatic tumors indicated for surgical resection and scheduled for open radical resection. This study was conducted at two institutions affiliated with the Hiroshima Surgical Study Group of Clinical Oncology (HiSCO). The primary endpoint was the proportion of massive intraoperative blood loss (≥ 1000 mL). The secondary endpoints were the amount of blood loss, operative time, parenchymal transection speed, postoperative complications, and mortality. The safety endpoints were device failure and adverse events associated with devices. Results: From June 2022 to May 2023, 20 patients were enrolled; one was excluded and 19 were included in the full analysis set (FAS). In the FAS, segmentectomy was performed in nine cases, sectionectomy in four cases, and hemihepatectomy in six cases. Radical resection was achieved in all patients. Intraoperative blood loss greater than 1000 mL was observed in five patients (26.3%). The median amount of blood loss was 545 mL (range, 180-4413), and blood transfusions were performed on two patients (10.5%). The median operative time was 346 minutes (range, 238-543) and the median parenchymal transection speed was 1.2 cm2/minute (range, 0.5-5.1). Postoperative complications of Clavien-Dindo classification ≥ Grade 3 occurred in four patients (21.1%). No mortalities occurred in this study. In the safety analysis, there were no device failures or adverse events associated with devices. Conclusions: This study demonstrated the safety and feasibility of DWT for liver resection. The efficacy of the DWT will be evaluated in future clinical trials.Keywords
This publication has 29 references indexed in Scilit:
- Posthepatectomy liver failure: A definition and grading by the International Study Group of Liver Surgery (ISGLS)Surgery, 2011
- Bile leakage after hepatobiliary and pancreatic surgery: A definition and grading of severity by the International Study Group of Liver SurgerySurgery, 2011
- Two-surgeon technique of parenchymal transection contributes to reduced transfusion rate in patients undergoing major hepatectomy: Analysis of 1,557 consecutive liver resectionsSurgery, 2010
- A clinical comparative analysis of crush/clamp, stapler, and dissecting sealer hepatic transection methodsHPB, 2008
- The use of water-jet dissection in open and laparoscopic liver resectionHPB, 2008
- Current techniques of liver transectionHPB, 2007
- Water-jet dissection for parenchymal division during hepatectomyHPB, 2006
- Two-Surgeon Technique for Hepatic Parenchymal Transection of the Noncirrhotic Liver Using Saline-Linked Cautery and Ultrasonic DissectionAnnals of Surgery, 2005
- Wasserstrahldissektion bei Leberresektion: Ultraschallaspirator versus Jet-Cutter - Eine prospektiv randomisierte Studie -Zentralblatt fur Chirurgie, 2001
- Results in 107 Hepatic Lobectomies with a Preliminary Report on the Use of a Clamp to Reduce Blood LossAnnals of Surgery, 1973