An Oscillator-Based CMOS Magnetosensitive Microarray Biochip With On-Chip Inductor Optimization Methodology
- 31 January 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (5) , 2556-2569
Abstract
This paper presents a high sensitivity oscillator-based CMOS magnetosensitive microarray biochip to detect clinical biomarkers in human samples and provide accurate information to diagnose human diseases. To increase the detection sensitivity, dynamic detecting range, and target number, a general methodology of designing an on-chip inductor with high quality factor, moderate size, and uniform surface magnetic field distribution is proposed, which meets all the electrical, magnetic and actual application requirements simultaneously, and also provides useful guidance for other oscillator-based magnetosensitive biochip design. As an implementation example, a microarray biochip with 14 sensor units in an area of 2.3 x 1.9 mm² is implemented in a 180-nm RF CMOS process to verify the biological sensing scheme and the correctness of the proposed theory and simulation. Finally, experiments using magnetic nanoparticles and cTnI were performed on our designed immunoassay detection system, which integrates the oscillator-based biosensor, microfluidic chip and immunoassay reagent into one platform for the first time, and the experimental results show a limit of detection of 50 pg/mL corresponding to 2.17 pM with a biological dynamic detecting range of 60 dB, proving the suitability of the biochip for quantitative analysis in practical medical diagnostics.Keywords
Funding Information
- National Natural Science Foundation of China (61674087)
- Guangdong Provincial Department of Science and Technology (2015B02023300, 2014215102)
- Tsinghua University Initiative Scientific Research Program
This publication has 34 references indexed in Scilit:
- Phase Noise and Fundamental Sensitivity of Oscillator-Based Reactance SensorsIEEE Transactions on Microwave Theory and Techniques, 2013
- A 256 Pixel Magnetoresistive Biosensor Microarray in 0.18 µm CMOSIEEE Journal of Solid-State Circuits, 2013
- Biological agent sensing integrated circuit (BASIC): A new CMOS magnetic biosensor system2012
- Quantification of protein interactions and solution transport using high-density GMR sensor arraysNature Nanotechnology, 2011
- A frequency-shift based CMOS magnetic biosensor with spatially uniform sensor transducer gain2010
- Effective magnetic permeability of Ni and Co micro- and nanoparticles embedded in a ZnO matrixJournal of Applied Physics, 2005
- On the design of RF spiral inductors on siliconIEEE Transactions on Electron Devices, 2003
- Electromagnetic and magnetic properties of multicomponent metal oxides heterostructures: Nanometer versus micrometer-sized particlesJournal of Applied Physics, 2003
- Simple accurate expressions for planar spiral inductancesIEEE Journal of Solid-State Circuits, 1999
- Analysis, design, and optimization of spiral inductors and transformers for Si RF ICsIEEE Journal of Solid-State Circuits, 1998