Diagnostic Accuracy of Ultrasonographic Respiratory Variation in the Inferior Vena Cava, Subclavian Vein, Internal Jugular Vein, and Femoral Vein Diameter to Predict Fluid Responsiveness: A Systematic Review and Meta-Analysis
Open Access
- 27 December 2021
- journal article
- review article
- Published by MDPI AG in Diagnostics
- Vol. 12 (1)
Abstract
This systematic review and meta-analysis aimed to investigate the ultrasonographic variation of the diameter of the inferior vena cava (IVC), internal jugular vein (IJV), subclavian vein (SCV), and femoral vein (FV) to predict fluid responsiveness in critically ill patients. Relevant articles were obtained by searching PubMed, EMBASE, and Cochrane databases (articles up to 21 October 2021). The number of true positives, false positives, false negatives, and true negatives for the index test to predict fluid responsiveness was collected. We used a hierarchical summary receiver operating characteristics model and bivariate model for meta-analysis. Finally, 30 studies comprising 1719 patients were included in this review. The ultrasonographic variation of the IVC showed a pooled sensitivity and specificity of 0.75 and 0.83, respectively. The area under the receiver operating characteristics curve was 0.86. In the subgroup analysis, there was no difference between patients on mechanical ventilation and those breathing spontaneously. In terms of the IJV, SCV, and FV, meta-analysis was not conducted due to the limited number of studies. The ultrasonographic measurement of the variation in diameter of the IVC has a favorable diagnostic accuracy for predicting fluid responsiveness in critically ill patients. However, there was insufficient evidence in terms of the IJV, SCV, and FV.Keywords
This publication has 62 references indexed in Scilit:
- Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility indexJournal of Surgical Research, 2013
- Applying Dynamic Parameters to Predict Hemodynamic Response to Volume Expansion in Spontaneously Breathing Patients With Septic ShockShock, 2013
- Prediction of fluid responsiveness in severe preeclamptic patients with oliguriaIntensive Care Medicine, 2012
- Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious useCritical Care, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoringCritical Care, 2009
- The Swan-Ganz Catheters: Past, Present, and FutureCirculation, 2009
- Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviewsJournal of Clinical Epidemiology, 2005
- The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessedJournal of Clinical Epidemiology, 2005
- Measuring inconsistency in meta-analysesBMJ, 2003