Determination of Positions, Velocities, and Kinetic Energies of Resonantly Excited Ions in the Quadrupole Ion Trap Mass Spectrometer by Laser Photodissociation
Authors:
- 1 October 1993
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 4 (10) , 792-797
Abstract
The effects on ion motion caused by the application of a resonance AC dipole voltage to the end-cap electrodes of the quadrupole ion trap are described. An excimer laser is used to photodissociate benzoyl ions, and its triggering is phase locked to the AC voltage to follow the motion of the ion cloud as a function of the phase angle of the AC signal. Resonantly excited ions maintain a coherent motion in the presence of He buffer gas, which dissipates energy from the ions via collisions. Maximum ion displacements, which depend upon the potential well depth (q z value), occur twice each AC cycle. Axial components of ion velocities are determined by differentiating the displacements of the distributions with respect to time. The experimental data show that these velocities are maximized when the ion cloud passes through zero axial displacement, and they compare favorably with results calculated using a simple harmonic oscillator model. Axial components of ion kinetic energies are low (<5 eV) under the chosen experimental conditions. At low values of q2 (≈ 0.2), the width of the ion distribution increases as the ion cloud approaches the center of the trap and decreases as it approaches the end-cap electrodes. This effect is created by compaction of the ion trajectories when ion velocities are decreased.Keywords
This publication has 31 references indexed in Scilit:
- Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratiosInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Extending the mass range of the quadrupole ion trap using axial modulationRapid Communications in Mass Spectrometry, 1989
- Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometryAnalytical Chemistry, 1987
- Collision-induced dissociation with Fourier transform mass spectrometryAnalytical Chemistry, 1982
- Radio-frequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trapJournal of Vacuum Science and Technology, 1980
- Fourier transform ion cyclotron resonance spectroscopyChemical Physics Letters, 1974
- Ion Cyclotron Resonance SpectroscopyScience, 1968
- Ion Cyclotron Resonance and the Determination of Collision Cross SectionsPhysical Review B, 1963
- Electrodynamic Containment of Charged ParticlesJournal of Applied Physics, 1959
- Die dreidimensionale Stabilisierung von Ladungstr gern in einem VierpolfeldThe European Physical Journal A, 1959