Rapid Prototyping forIn VitroKnee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material
Open Access
- 24 March 2015
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-9
Abstract
Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components forin vitrotests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components forin vitroTKA studies and future investigations on knee biomechanics.Keywords
This publication has 41 references indexed in Scilit:
- Patellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurementBioMedical Engineering OnLine, 2013
- Prototyping for Surgical and Prosthetic TreatmentJournal of Craniofacial Surgery, 2011
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-StudienBiomedical Engineering / Biomedizinische Technik, 2009
- The influence of muscle load on tibiofemoral knee kinematicsJournal of Orthopaedic Research, 2009
- A review of rapid prototyping techniques for tissue engineering purposesAnnals of Medicine, 2008
- Der Einfluß von Kniegelenkbeugung und Femurrotation auf den retropatellaren Kontakt des menschlichen Kniegelenkes - Influence of Flexion of the Knee and Femoral Rotation on Retröpatellar Contact in HumansBiomedical Engineering / Biomedizinische Technik, 1999
- Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplastyBiomaterials, 1997
- Der Einfluß der Oberflächenenergie auf das Abriebverhalten von Materialpaarungen für das künstliche Hüftgelenk. Influence of Surface Energy on Wear for Various Material Combinations in Hip Joint ReplacementsBiomedical Engineering / Biomedizinische Technik, 1996
- Methode zur In-vivo-Messung des intraossären Druckes an der Patella - In Vivo Measurement of the Intra-osseous Pressure of the Human PatellaBiomedical Engineering / Biomedizinische Technik, 1992