Oxidation of catechols during positive ion electrospray mass spectrometric analysis: Evidence for in‐source oxidative dimerization
- 1 September 2014
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (20) , 2181-2190
Abstract
RATIONALE: Catechols are an important class of analytes occurring in many natural and synthetic products. Electrospray ionization in negative mode is the preferred way of ion generation for these compounds; however, studies in positive ion mode can reveal their potential for in‐source oxidation and further structural changes, some of which may also occur in the solution phase. Therefore in‐source oxidation can provide a forward look into the potential for solution oxidation. METHODS: 1:1 Acetonitrile/water solutions of catechol (Cat), 4,5‐dichlorocatechol (4,5‐DCC), 3,4‐dichlorocatechol (3,4‐DCC) and tetrachlorocatechol (TCC) were analyzed by positive ion ultrahigh‐performance liquid chromatography (UHPLC/ESI‐MS) and UHPLC/ESI‐MS/MS under various emitter voltages to assess their liability towards in‐source oxidation. Structural information for in‐source generated compounds was obtained through the use of product ion scans. RESULTS: Using catechols as probe compounds, we have demonstrated that under the conditions used in many analytical laboratories in‐source oxidation can severely affect the sensitivity and response functions of an analyte. Under standard UHPLC conditions (300 μL/min flow rate), Cat, 3,4‐DCC, 4,5‐DCC and TCC can undergo in‐source oxidation. The extent of oxidation is dependent either on the instrument or on the characteristics of the emitter. This is evident by a change in the isotopic pattern of these compounds and the generation of ions at lower m/z values due to a loss of 1 and/or 2 hydrogens and electrons. In the case of catechol, the formation of a dimer resulting from in‐source oxidation reactions was observed. This dimer has the same fragmentation pattern as the dimer generated by oxidation in the solution phase. CONCLUSIONS: The present work demonstrates the potential of positive ion ESI for oxidizing electroactive compounds during regular analytical operation using commercially available mass spectrometers. Using Cat and some of its chlorinated analogues as probe compounds, we have demonstrated that under the conditions used in many analytical laboratories in‐source oxidation and dimerization can and does take place. Copyright © 2014 John Wiley & Sons, Ltd.Keywords
This publication has 26 references indexed in Scilit:
- Ascorbic acid for homogenous redox buffering in electrospray ionization–mass spectrometryAnalytical and Bioanalytical Chemistry, 2012
- Structural Determinant of Chemical Reactivity and Potential Health Effects of Quinones from Natural ProductsChemical Research in Toxicology, 2011
- Poly(3,4‐ethylenedioxypyrrole)‐modified emitter electrode for substitution of homogeneous redox buffer agent hydroquinone in electrospray ionization mass spectrometryRapid Communications in Mass Spectrometry, 2010
- Scales of Oxidation Potentials, pKa, and BDE of Various Hydroquinones and Catechols in DMSOThe Journal of Organic Chemistry, 2010
- Natural Abiotic Formation of Furans in SoilEnvironmental Science & Technology, 2010
- Absorption Spectrum, Mass Spectrometric Properties, and Electronic Structure of 1,2-BenzoquinoneThe Journal of Physical Chemistry A, 2010
- Minimizing analyte electrolysis in electrospray ionization mass spectrometry using a redox buffer coated emitter electrodeRapid Communications in Mass Spectrometry, 2010
- Dimerization of ionized 4‐(methyl mercapto)‐phenol during ESI, APCI and APPI mass spectrometryJournal of Mass Spectrometry, 2009
- Expanded Electrochemical Capabilities of the Electrospray Ion Source Using Porous Flow-Through Electrodes as the Upstream Ground and Emitter High-Voltage ContactAnalytical Chemistry, 2005
- Study and Application of a Controlled-Potential Electrochemistry−Electrospray Emitter for Electrospray Mass SpectrometryAnalytical Chemistry, 2005